2. Control Software Manual
n Set-up of evaluation board and control software
1. Set up the AKD4366 according to previous term.
2. Connect IBM-AT compatible PC with AKD4366 by 10-line type flat cable (packed with AKD4366). Take care of the
direction of 10pin header. (Please install the driver in the CD-ROM when this control software is used on Windows
2000/XP. Please refer “Installation Manual of Control Software Driver by AKM device control software”. In case of
Windows95/98/ME, this installation is not needed. This control software does not operate on Windows NT.)
3. Insert the CD-ROM labeled “AK4366 Evaluation Kit” into the CD-ROM drive.
4. Access the CD-ROM drive and double-click the icon of “akd4366.exe” to set up the control program.
5. Then please evaluate according to the follows.
n Operation flow
Keep the following flow.
1. Set up the control program according to explanation above.
2. Click “Port Setup” button.
3. Click “Write default” button.
Then set up the dialog and input data.
n Explanation of each buttons
1. [Port Setup] : Set up the printer port.
2. [Write default] : Initialize the register of AK4366.
3. [Function1] : Dialog to write data by keyboard operation.
4. [Function2] : Dialog to evaluate ATT.
5. [Write] :
Dialog to write data by mouse operation.
<KM071400>
-7-
2003/03