9. Electrical Characteristics
Table 5. Electrical characteristics.
Conditions (unless otherwise specified): Ta = 35°C, VDD = 3.3V
Parameter
Symbol
Conditions
Min. Typ. Max. Units
Current Consumption
Sensitivity
(Note 1, Note 2, Note 3)
IDD No loads
Vh See paragraph 10.1
6.2 9.6
128.7 130.0 131.3
mA
mV/A
Zero-Current Output Voltage
(Note 1, Note 2)
Vof See paragraph 10.1
1.636 1.650 1.664
V
Linear Sensing Range
Output Saturation Voltage H
INS
VsatH
IOUT = −0.5mA
−10.1
VDD
−0.3
10.1
A
V
Output Saturation Voltage L
VsatL IOUT = +0.5mA
Linearity Error
(Note 1, Note 2)
ρ See paragraph 10.2
−0.6
0.3
V
0.6 %F.S.
Rise Response Time
tr
CL = 100pF,
see paragraph 10.5
0.5
µs
Fall Response Time
tf
CL = 100pF,
see paragraph 10.5
0.5
µs
Bandwidth
Output Noise
Temperature Drift of
Sensitivity (Note 2)
fT
VNrms
Vh-dmax
−3dB, CL = 100pF
100Hz to 4MHz
Ta = −40 to 90°C
Reference temperature Ta =
35°C
1000
1.2
±0.7
kHz
mVrms
%
Temperature Drift of
Ta = −40 to 90°C
Zero-Current Output Voltage Vof-dmax Reference temperature Ta =
±9
mV
(Note 2)
35°C
Ratiometricity Error of
Sensitivity (Note 2)
Vh-R VDD = 2.97V to 3.63V
−1.0
1.0
%
Ratiometricity Error of
Zero-Current Output Voltage Vof-R VDD = 2.97V to 3.63V,
−0.8
(Note 2)
0.8
%F.S.
Primary Conductor
Resistance (Note 4)
R1
1.6
mΩ
Total Accuracy (Note 5)
Isolation Voltage(Note 6)
Isolation Resistance
(Note 4)
ETO Ta = −40 to 90°C
VINS AC 50/60Hz, 60s
RINS DC 1kV
±1.3
3.0
500
%F.S.
kV
MΩ
Clearance Distance
(Note 4)
dCL
between primary and
secondary conductors
5.0 5.2
mm
Creepage Distance
(Note 4)
dCP
between primary and
secondary conductors
5.0 5.2
mm
Note 1. These parameters can drift by long-term use or reflow process. Please see ‘14. Reliability Tests’ for the
reference of drift values.
Note 2. The primary current (IIN) is swept within ±6A. Current is applied within 35ms in each step.
Note 3. This parameter is tested on condition that current density is uniform. Sensitivity may change slightly
depending on a primary conductor layout on PCB. Please see the application note provided in the
AKM website.
Note 4. These parameters are guaranteed by design.
016008762-E-00
-6-
2016/07