English
Language : 

AKD5358B-B Datasheet, PDF (6/20 Pages) Asahi Kasei Microsystems – AK5358B Evaluation Board Rev.0
[AKD5358B-B]
MEASUREMENT RESULTS
[Measurement condition]
• Measurement unit
• MCLK
• SCLK
• fs
• Bit
• Power Supply
• Interface
• Temperature

: Audio Precision, System Two Cascade
: 256fs
: 64fs
: 48kHz, 96kHz
: 24bit
: VA = 5.0V, VD = 5.0V
: DIT
: Room
fs=48kHz
Parameter
Input signal
Measurement filter
S/(N+D)
1kHz, -1dB
20kLPF
20kLPF
DR
1kHz, -60dB
20kLPF, A-weighted
20kLPF
S/N
No input
20kLPF, A-weighted

fs=96kHz
Parameter Input signal Measurement filter
S/(N+D)
1kHz, -1dB
40kLPF
40kLPF
DR
1kHz, -60dB
40kLPF, A-weighted
S/N
No input
40kLPF
40kLPF, A-weighted

Results
L ch
R ch
93.1 dB
99.6 dB
102.1 dB
100.0 dB
103.0 dB
93.0 dB
99.8 dB
102.6 dB
99.9 dB
102.8 dB
Results
L ch
R ch
95.1 dB
99.4 dB
94.9 dB
99.4 dB
104.6 dB
104.7 dB
99.5 dB
99.4 dB
105.0 dB
104.8 dB
<KM099502>
-6-
2010/01