English
Language : 

AK1110AEU Datasheet, PDF (6/19 Pages) –
8. Recommended Operating Conditions
Parameter
Symbol Min. Typ. Max. Unit
Operating Temperature Range
Ta
-40
-
85 °C
Operating junction temperature
Tj
-40
125 °C
Operating Voltage Range
VIN
6
-
14
V
Note 6. All voltages are with respect to GND. GND=0V
[AK1110AEU]
Comments
9. Electrical Characteristics
(Ta= −40°C ~ +85°C, VIN=VEN=6.0V, CIN=1.0uF, CNP1=CNP2=10uF, COUT1=COUT2=10uF)
Parameter
Symbol
Test Conditions
Min. Typ. Max.
Common items of LDO1 and LDO2
Quiescent Current
IQ
IOUT = 0mA
-
3.0 5.0
Ground Terminal
Current
IGND
IOUT1+IOUT2 =32mA
-
5.0 7.0
Standby Current
ISTANDBY VEN=0V
-
0.01 2.0
EN terminal high level
VENH
1.8
-
-
EN terminal Low level
VENL
-
-
0.35
EN Terminal Current
IENLKG VEN=1.8V
-
50 150
EN terminal on time
(Note 10)
tENON
-
55 100
Thermal protection
Shutdown Temperature
TTSD
135
-
155
LDO1
Output Voltage
Line Regulation
Load Regulation
Dropout Voltage
Maximum Output
Current (Note 9)
Output noise(Note 8)
Ripple rejection
(Note 8)
LDO2
VOUT1
LinReg1
LoaReg1
VDROP1
IOUT1= 1mA to 200mA
∆VIN1 = 5V
IOUT1= 1mA to 200mA
IOUT1 = 200mA
IOUTMAX1 VOUT1 = VOUT1(typ)×0.9
Vnoise1
PSRR1
IOUT1=100mA, f=10Hz
to100kHz
IOUT1 = 100mA, f=1kHz
IOUT1 = 100mA, f=100kHz
IOUT1 = 100mA, f=1MHz
4.90 5.0 5.10
6
20
50
600
220
2.0
83
80
70
Output Voltage
Line Regulation
Load Regulation
Dropout Voltage
Maximum Output
Current (Note 9)
VOUT2
LinReg2
LoaReg2
VDROP2
IOUT2= 1mA to 100mA
∆VIN2 = 5V
IOUT2 = 1mA to 100mA
IOUT2 = 100mA
IOUTMAX2 VOUT2 = VOUT2(typ)×0.9
4.90 5.0 5.10
5
15
25
600
120
Unit
mA
mA
µA
V
V
µA
ms
°C
V
mV
mV
mV
mA
µVRMS
dB
dB
dB
V
mV
mV
mV
mA
016016348-E-00
-6-
2016/12