English
Language : 

AK8776 Datasheet, PDF (4/11 Pages) Asahi Kasei Microsystems – Hall IC for Pulse Encoder
[AK8776]
Magnetic Characteristics
The output F and D is processed signals from internal signal A and B which is determined by the applied magnetic
field and threshold level BopV, BrpV, BopH and BrpH as follows.
Table 6. Magnetic characteristics(Ta = 25°C, VDD = 3.0V)
Parameter
Symbol Min. Typ. Max. Unit
Vertical magnetic field
operating point
BopV
1.5
4.0
mT
Vertical magnetic field
releasing point
BrpV
−4.0
−1.5
mT
Horizontal magnetic field
operating point
BopH
1.5
4.0
mT
Horizontal magnetic field
releasing point
BrpH
−4.0
−1.5
mT
Hysteresis
BhV, BhH
3.0
mT
(*1) Horizontal magnetic flux density is zero.
(*2) Vertical magnetic flux density is zero.
Note
(*1)
(*1)
(*2)
(*2)
(*1), (*2)
MS1317-E-00
4
2011/July