AK2548 Datasheet, PDF (19/30 Pages) Asahi Kasei Microsystems – 7 channel E1 Transceiver | |||
|
◁ |
ASAHI KASEI
[AK2548]
STATUS REGISTER
Symbol
LOSx
(x=1 to 7)
LOTCx
(x=1 to 7)
LOMC
Description
Loss of signal alarm for channel x. Read only register.
When the loss of signal or the loss of MCLK are detected, LOSx goes High.
Loss of TCLK alarm for channel x. Read only register.
When the loss of TCLKx is detected, LOTCx goes High.
Loss of MCLK alarm. Read only register.
When the loss of MCLK is detected, LOMC and LOSx go High.
MASK CONTROL REGISTER
Symbol
MLOSx
(x=1 to 7)
MLOTCx
(x=1 to 7)
MLOMC
Description
Mask loss of signal alarm for channel x.
MLOSx is active-high to prevent LOSx from setting INT output âhighâ .
It is possible to read LOSx register regardless of the status of MLOSx.
Initial value is âhighâ.
Mask loss of TCLK alarm for channel x .
MLOTCx is active-high to prevent LOTCx from setting INT output âhighâ .
It is possible to read LOTCx register regardless of the status of MLOTCx.
Initial value is âhighâ.
Mask loss of MCLK alarm.
MLOMC is active-high to prevent LOMC from setting INT output âhighâ .
It is possible to read LOMC register regardless of the status of MLOMC.
Initial value is âhighâ.
Note) Please refer to âLoss of MCLK theory of operationâ. (P25)
CHANNEL CONTROL REGISTER
Symbol
RLOOPx/
LLOOPx
POLNx
PDx
MSKx
RDEN
TAOSx
ECx
Description
Loopback mode of channel x is activated through the setting of these register
as shown below in Table 1.
TIPx/RINGx output polarity is controlled by this register as shown below in
Table 2. Initial value is âhighâ.
PDx is active-high to set the corresponding transceiver in power down mode.
TTIPx and TRINGx go âlowâ. LOSx goes âhighâ in power down mode.
Initial value is âhighâ.
MSKx is active-high to prevent LOSx or LOTCx from setting INT output
âhighâ. Initial value is âhighâ.
RDEN is active-high to prevent RCLK, RPOS, and RNEG output from
forcing to âlowâ or âhighâ by the detection of Loss of signal. Initial value is
âlowâ.
TAOS is active-high to output all oneâs signal from TTIPx and TRINGx.
All oneâs signal synchronized with TCLK. When TCLK is lost, the signal
synchronized with MCLK.
Application is selected by this register in Table 3. Initial value is low.
C0028-E-00
19
1999/9
|
▷ |