English
Language : 

AKD5602A Datasheet, PDF (13/24 Pages) Asahi Kasei Microsystems – Evaluation board for AK5602A
5 - 6. Measured data displaying screen
[AKD5602A]
(1) Displaying data for one second to be selected from entered period can be specified by manipulating UP/DOWN button.
80 samples of data will be displayed for every measurement.
(2) Specified data will be displayed on the screen when “To display” button is pressed.
(3) Measured data which are specified by symbols are represented in either 16 bit hexadecimal data format or 32 bit
hexadecimal data format.
(4) F1_CNT, F2_CONT, and F3_CNT display the number of pulses for one second in hexadecimal format at F1, F2, and
F3 pin of the AK5602A respectively. Each number represents the digitized frequency of each voltage input.
(5) RPO, TPO, RQO, and TQO display the number of pulses for one second in hexadecimal format at the respective pin of
the AK5602A. RPO and TPO represent the number of pulses for one second of active energy. On the other hand,
RQO and TQO represent the number of pulses for one second of reactive energy.
(6) Display period (seconds) of data will be a period set by “Display data setting up screen”. The initial value of the period
is 10 seconds.
(7) The screen will jump to “Measuring screen” when “Return” button is pressed.
<KM105100>
- 13 -
2010/10