English
Language : 

AKD4682-A Datasheet, PDF (12/51 Pages) Asahi Kasei Microsystems – 24bit CODEC that has two channels of ADC and four channels of DAC
ASAHI KASEI
[AKD4682-A]
Control Software Manual
„ Set-up of evaluation board and control software
1. Set up the AKD4682-A according to previous term.
2. Connect IBM-AT compatible PC with AKD4682-A by 10-line type flat cable (packed with AKD4682-A). Take care
of the direction of 10pin header. (Please install the driver in the CD-ROM when this control software is used on
Windows 2000/XP. Please refer “Installation Manual of Control Software Driver by AKM device control software”.
In case of Windows95/98/ME, this installation is not needed. This control software does not operate on Windows
NT.)
3. Insert the CD-ROM labeled “AKD4682-A Evaluation Kit” into the CD-ROM drive.
4. Access the CD-ROM drive, and double-click the icon of “akd4682-a.exe”, and set up the control program.
akd4682-a.exe: AK4682-A control program
5. Then evaluate according to the follows.
„ Operation flow
Keep the following flow.
1. Set up the control program according to explanation above.
2. Click “Port Reset” button.
„ Explanation of each buttons
1. [Port Reset]:
2. [Write default]:
3. [All Write]:
4. [Function1]:
5. [Function2]:
6. [Function3]:
7. [Function4]:
8. [Function5]:
9. [SAVE]:
10. [OPEN]:
11. [Write]:
Set up the USB interface board (AKDUSBIF-A).
Initialize the registers.
Write all registers data that is currently displayed.
Dialog to write data by keyboard operation.
Dialog to write data by keyboard operation.
The sequence of register setting can be set and executed.
The sequence that is created on [Function3] can be assigned to buttons and
executed.
The register setting that is created by [SAVE] function on main window can
be assigned to buttons and executed.
Save the current register setting.
Write the saved values to all register.
Dialog to write data by mouse operation.
„ Indication of data
Input data is indicated on the register map. Red letter indicates “H” or “1” and blue one indicates “L” or “0”. Blank is the
part that is not defined in the datasheet.
<KM086400>
- 12 -