AT1362A/B
Preliminary Product Information
Synchronous Buck Converter
With Power Good Detector & LDO
Electrical Characteristics
(VCC = 3.6V,Ta =+25℃ , unless otherwise noted. )
Parameter
Symbol
Condition
Values
Unit
Min. Typ. Max.
DC/DC CONVERTER
VCC UVLO
VUV VCC=3V→2V Sweep
- 2.4 -
V
UVLO Hysteresis width
VUVHY
Input Supply Range
VCC
Quiescent Current
IS Active Mode
Output1 Voltage Accuracy
Output1 Voltage
line-regulation
Output1 Variation
with Temperature
VOUT1
VOUT1-Line VCC=3.5V to 6.0V
Ta =-20℃ to +85℃
Feedback current
IOUT1
Current Limit
Maximum Output Current
ICL1 VIN=5V, VOUT1=2.5V/1.8V
IO
VIN=5V, VOUT1=2.5V/1.8V,
L=4.7uH
Oscillator Frequency
fosc1 Vout1=2.5V/1.8V
fosc2 Vout1=0V
RDS(ON) of P-Channel
MOSFET
RDS(ON) of N-Channel
MOSFET
RPFET
RNFET
ILX= 300mA
ILX= -300mA
SW Leakage Current
ISWL
- 100 - mV
2.5 - 6.0 V
- 500 - µA
-2 - +2 %
- 0.1 0.5 %
- 0.5 1.0 %
- 6 - uA
0.6 0.7 0.8 A
400 -
- mA
0.8 1.0 1.2 MHz
- 200 -- KHz
- 0.3 0.4 Ω
- 0.25 0.35 Ω
- ±0.1 ±1 µA
CONTROL BLOCK
PG on voltage
VPGON IPG=1mA
PG Hysteresis width
VPGTHYS
PG pin leak current
IPGTLK VPG=5.0V
LDO control on Hysteresis
width
VLDTHYS
DELAY Pin Charge Current IDELAY
-
- 0.4 V
- 80 - mV
-
-
1 uA
- 80 - mV
0.8 1.0 1.2 uA
LDO
Output2 Voltage Accuracy
Current Limit
Dropout Voltage
Load Regulation
Line Regulation
Ripple Rejection Rate
OUT2 Leakage Current
VOUT2
-2 - +2 %
ICL2
450 -
- mA
VDV IOUT2=400mA
- 400 600 mV
∆VOUT2 IOUT2=1mA→ 100mA
- 15 50 mV
LR IOUT2=100mA, VOUT1=3.6V→6.0V - 0.05 0.25 %
PSRR IOUT2=100mA, f=1kHz
- 60 - dB
IOUT2LK
- 6 - uA
7F, No.9, Park Avenue II, Science-Based Industrial Park, Hsinchu 300,Taiwan, R.O.C.
Tel: 886-3-563-0878 Fax: 886-3-563-0879
WWW: http://www.aimtron.com.tw
5/30/2006 REV:1.0
Email: service@aimtron.com.tw
4