English
Language : 

AT1382B Datasheet, PDF (14/21 Pages) Aimtron Technology – 4-Channel DC-DC Converter for DSC
AT1382B
Preliminary Product Information
4-Channel DC-DC Converter for DSC
5. Soft start setting
The soft start operation is determined by the capacitor connected to the CS1~CS4 terminal.
Consider the input voltage and load current to design the soft start time.
The soft start time until the DC/DC converter output voltage reaches 95%. It can calculate the soft
start time Ts (s).
Ts (s) = 0.084 * CS (μF)
−( Ts )
VCS = 0.7 × (1 − e ) R×Cs
R = 33.6 ×117.6 KΩ
33.6 + 117.6
The soft start function of CH1 to CH4 are the same. It could be disabled soft start function by
floating CS pin.
6. Setting the output voltage
2F, No.10, Prosperity RD. II, Science-Based Industrial Park, Hsinchu 300,Taiwan, R.O.C.
Tel: 886-3-563-0878
WWW: http://www.aimtron.com.tw
Fax: 886-3-563-0879
Email: service@aimtron.com.tw