English
Language : 

AME25-JZ Datasheet, PDF (5/5 Pages) AIMTEC – 25 Watt | AC-DC / DC-DC Converter
AME20‐12SJZ
Trim down %
Vout (VDC)
Rt down (KΩ)
Trim up %
Vout (VDC)
Rt up (KΩ)
1
11.88
183.233
1
12.12
211.778
2
11.76
111.59
2
12.24
57.03
3
11.64
79.474
3
12.36
32.596
4
11.52
61.246
4
12.48
22.642
5
11.4
49.499
5
12.6
17.238
Series AME25-JZ
25 Watt | AC-DC / DC-DC Converter
6
11.28
41.299
6
12.72
13.845
7
11.16
35.249
7
12.84
11.516
8
11.04
30.602
8
12.96
9.819
9
10.92
26.921
9
13.08
8.527
10
10.8
23.933
10
13.2
7.511
AME20‐15SJZ
Trim down %
1
2
3
4
5
6
7
8
9
10
Vout (VDC)
14.85 14.7 14.55 14.4 14.25 14.1 13.95 13.8 13.65 13.5
Rt down (KΩ) 616.5
304 199.833 147.75 116.5 95.667 80.786 69.625 60.944
54
Trim up %
1
2
3
4
5
6
7
8
9
10
Vout (VDC)
15.15 15.3 15.45 15.6 15.75 15.9 16.05 16.2 16.35 16.5
Rt up (KΩ)
124
61.5 40.667 30.25
24 19.833 16.857 14.625 12.889 11.5
AME20‐24SJZ
Trim down %
Vout (VDC)
Rt down (KΩ)
Trim up %
Vout (VDC)
Rt up (KΩ)
1
23.76
471.081
1
24.24
239.556
2
23.52
287.942
2
24.48
64.606
3
23.28
205.845
3
24.72
36.982
4
23.04
159.249
4
24.96
25.728
5
22.8
129.221
5
25.2
19.619
6
22.56
108.258
6
25.44
15.783
7
22.32
92.793
7
25.68
13.15
8
22.08
80.914
8
25.92
11.232
9
21.84
71.504
9
26.16
9.771
10
21.6
63.865
10
26.4
8.622
AME20‐48SJZ
Trim down %
Vout (VDC)
Rt down (KΩ)
Trim up %
Vout (VDC)
Rt up (KΩ)
1
47.52
5501.011
1
48.48
420.217
2
47.04
2921.325
2
48.96
191.396
3
46.56
1974.775
3
49.44
123.671
4
46.08
1483.386
4
49.92
91.211
5
45.6
1182.489
5
50.4
72.163
6
45.12
979.298
6
50.88
59.636
7
44.64
832.871
7
51.36
50.773
8
44.16
722.336
8
51.84
44.17
9
43.68
635.938
9
52.32
39.06
10
43.2
566.549
10
52.8
34.99
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer
controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary
based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C,
humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all
internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for
release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications
which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available
at www.aimtec.com.
www.aimtec.com
F 052e R8.B
Tel: +1 514 620 2722
5 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only