English
Language : 

AMEL10-MAZ_16 Datasheet, PDF (3/6 Pages) AIMTEC – 10 Watt | AC-DC / DC-DC Converter
Series AMEL10-MAZ
10 Watt | AC-DC / DC-DC Converter
Safety Specifications
Parameters
Agency approvals
Standards
cULus, CE, CB
Medical Electrical Equipment
Information technology Equipment
EMI - Conducted and radiated emission
Harmonic Current Emissions
Voltage fluctuations and flicker
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
Surge Immunity
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Voltage dips, Short Interruptions Immunity
Information Technology Equipment
Information Technology Equipment
IEC\EN\UL 60601-1, 2 x MOOP, CSA-C22.2 No.
601.1-M90
EN 60950-1:2006+A11:2009
EN55022, class B
IEC/EN 61000-3-2, Class A
IEC/EN 61000-3-3, (EN60555-3)
IEC 61000-4-2 Level 3
IEC 61000-4-3 Level 2
IEC 61000-4-4 Level 2
IEC 61000-4-5 Level 3
IEC 61000-4-6 Level 2
IEC 61000-4-8
IEC 61000-4-11
UL 60950-1:2007
CAN/CSA-C22.2 No.60950-1-07
Additional Surge Protective Circuitry
The AMEL10-MAZ series design level surge protection is certified to IEC 61000-4-5 surge Line to Line of 1KV. However
greater protection can be enhanced by adding protective devices to ingress circuitry. For example, by adding an MOV (Metal
Oxide Varistor) device example TVR10471KSY to the N / L input lines 2KV surge protection or greater, can be achieved.
MOV PN
TVR10471KSY
Vrms
V
300
Vdc
Wmax (2ms)
Pmax
V
J
W
385
70
0.4
Pin Out Specifications
Pin
Single
1
AC Input (N)
2
AC Input (L)
3
+V Output
4
-V Output
5
No pin
Dual positive
AC Input (N)
AC Input (L)
+V1 Output
Common
+V2 Output
Dual negative/positive
AC Input (N)
AC Input (L)
+V1 Output
Common
-V2 Output
www.aimtec.com
F 052e R8.U
Tel: +1 514 620 2722
3 of 6
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only