English
Language : 

AM1DC-Z Datasheet, PDF (3/3 Pages) AIMTEC – 1 Watt | DC-DC Converter
Safety Specifications
Parameters
Standards
Designed to meet IEC 60950-1: 2001
Pin Out Specifications
Pin
6000 VDC
Single
Dual
1
+ V Input
+ V Input
2
- V Input
- V Input
5
- V Output
- V Output
6
No pin
Common
7
+ V Output + V Output
Dimensions
19.56
(0.77)
12.00
(0.47)
9.80
(0.39)
PRINTED
FACE
12.50
(0.49)
0.50
(0.02)
2.54
(0.10)
15.20
(0.60)
3.50
(0.14)
0.50
(0.02)
Series AM1DC-Z
1 Watt | DC-DC Converter
Derating
Free Air Convection
100
70ºC
80
60 Safe Operating Area
40
20
0
-40 -20
0
20
40
60
80 85 100
Ambient Temperature º C
9.80
(0.39)
0.50
(0.02)
0.25
(0.01)
2.40
(0.09)
Recommended Application circuit for reducing the output ripple and noises:
Recommended Output Capacitor to reduce the converter’s ripple and noises for single output models is 4.7µF to 100µF and for dual
output models is 4.7µF to 68µF connected to both outputs.
Li with value of 12µH and Ci with value 10µF to 100µF are recommended to be connected to the input of the converter for EMI
improvement.
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R6.E
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only