English
Language : 

AMES15-MAZ Datasheet, PDF (2/5 Pages) AIMTEC – 15 Watt | AC-DC Converter
Series AMES15-MAZ
15 Watt | AC-DC Converter
Isolation Specifications
Parameters
Tested I/O voltage
Isolation resistance
Conditions
3 sec
Typical
>1000
Rated
4000
Units
VAC
MΩ
General Specifications
Parameters
Conditions
Typical
Maximum
Switching frequency
132
Start up time
900
Over load protection
Auto recovery, hiccup mode
>131
Over voltage protection
Zener diode clamp
Short circuit protection
Continuous
Short Circuit restart
Operating temperature
With derating over 55 oC (10CFM)
Auto recovery
-40 to +80
Storage temperature
-50 to +100
Max Case temperature
100
Temperature coefficient
±0.02
Cooling
Free air convection
Humidity
95
Weight
100
Dimensions (L x W x H)
MTBF
3.62 x 2.56 x 0.94 inches 92.0 x 65.0 x 24.0 mm
> 400 000hrs (MIL-HDBK -217F, t=+25oC)
Units
KHz
mS
%
oC
oC
oC
% / oC
% RH
g
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Environment Approval
Parameters
Conditions
Wave form: Half sine wave
Acceleration amplitude: 5gn
Shock
Bump duration: 30 ms
Number of bumps: 18 (3 in each direction for every axis)
Converter operation before and after test, body mounted (on chassis)
Test mode: Sweep sine
10-100Hz, speed 0.05Hz/s
Vibrations
Displacement: 1mm
Acceleration: 3g
3 loops 30min one cycle, 3h total, every axis tested
Converter operation before and after test, body mounted (on chassis)
Safety & EMC Specifications
Parameters
Agency approvals cULus, CE, CB
Medical Electrical Equipment
Information technology Equipment
EMI - Conducted and radiated emission
Harmonic Current Emissions
Voltage fluctuations and flicker
Standards
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
Surge Immunity
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Voltage dips, Short Interruptions Immunity
IEC\EN\UL 60601-1, CSA-C22.2 No. 601.1-M90
EN 60950-1:2006+A11:2009
EN55011, class B
IEC/EN 61000-3-2, (EN60555-2)
IEC/EN 61000-3-3, (EN60555-3)
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-11
www.aimtec.com
F 052e R7.L
Tel: +1 514 620 2722
2 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only