Output Specifications
Parameters
Conditions
Typical
Current accuracy (CC Mode)
±3
Voltage accuracy (CV Mode)
±3
Line regulation
LL-HL
±1
Load regulation
0-100% load
±3
Ripple & Noise ④
20MHz Bandwidth
75
Hold-up time
90
Current adjustment range
100-0
Minimum Load Voltage
See the models table
④ Tested with 0.1µF (C/C) or (M/C) and 47µF (E/C) parallel capacitors at the end.
Maximum
Units
%
%
%
%
mV p-p
ms
%
Isolation Specifications
Parameters
Tested I/O voltage
Isolation Resistance
Isolation Capacitance
Conditions
3 sec/3.5mA
500VDC
Typical
>1000
1000
Rated
3000
Units
VAC
MΩ
pF
General Specifications
Parameters
Switching frequency
Over current protection
Over voltage protection
Short circuit protection
Short circuit restart
Over temperature protection
Operating temperature
Maximum case temperature
Storage temperature
Temperature coefficient
Cooling
Humidity
Case material
Potting
Wires
Weight
Dimensions (L X H X W)
MTBF
Conditions
Typical
Maximum
130
AMEPR60C-50120AZ
1.27
AMEPR60C-36170AZ
1.77
AMEPR60C-24250AZ
2.55
AMEPR60C-12500AZ
5.2
Refer to Constant Current vs. Constant Voltage Mode curve
Continuous
Auto recovery
>105°C
With derating over 55°C
-40 to +85
100
-40 to +95
±0.02
Free air convection
95
Plastic
Epoxy (IP67 rated)
UL1015 18AWG *20CM
530
5.30 x 2.27 x 1.59 inches 134.80 x 57.68 x 40.50 mm
>400,000 hrs (MIL-HDBK-217F at +25°C)
Units
KHz
A
oC
oC
oC
% / oC
% RH
g
Safety Specifications
Parameters
Agency approvals cULus, CE
UL8750, UL60950-1, EN55022, class B, EN60529(IP68), EN61347-1, EN61347-2-13
Information Technology Equipment
EN55022 Class B
Harmonic Current Emissions
IEC/EN 61000-3-2, Class C
Voltage fluctuations and flicker
IEC/EN 61000-3-3, (EN60555-3)
Electrostatic Discharge Immunity
IEC 61000-4-2 Level 3
Standards
RF, Electromagnetic Field Immunity
IEC 61000-4-3 Level 2
Electrical Fast Transient / Burst Immunity
IEC 61000-4-4 Level 2
Surge Immunity
IEC 61000-4-5 Level 3
RF, Conducted Disturbance Immunity
IEC 61000-4-6 Level 2
Power frequency Magnetic Field Immunity
IEC 61000-4-8 Level 1
Voltage dips, Short Interruptions Immunity
IEC 61000-4-11
www.aimtec.com
F 052.1e R3.G
Tel: +1 514 620 2722
2 of 13
Toll free: + 1 888 9 AIMTEC
(924 6832)