English
Language : 

AMEOS30-MAZ_16 Datasheet, PDF (2/4 Pages) AIMTEC – 30 Watt | AC-DC / DC-DC Converter
Isolation Specifications
Parameters
Tested I/O voltage
Isolation Resistance
Conditions
60 sec
Series AMEOS30-MAZ
30 Watt | AC-DC / DC-DC Converter
Typical
>1000
Rated
4000
Units
VAC
MΩ
General Specifications
Parameters
Switching frequency
Protection class
Over current protection
Over voltage protection
Short circuit protection
Short Circuit restart
Operating temperature
Maximum case temperature
Storage temperature
Temperature coefficient
Cooling
Humidity
Weight
Dimensions (L X H X W)
MTBF
Conditions
Typical
Maximum
47
Class II
Auto recovery
110
140
Zener diode clamp
110
Hiccup mode, indefinite
Auto recovery
With derating above 60ºC
-40 - +85
100
-40 to +95
0.02
Free air convection
Non condensing
95
145
4.92 x 2.32 x 1.02 inches / 125 x 59 x 26mm
> 800,000 hrs (MIL-HDBK -217F, t=+25 oC)/Full Load
> 200,000 hrs (MIL-HDBK -217F, t=at highest operating temperature)/Full Load
Units
KHz
%
%
oC
oC
oC
% / oC
% RH
g
Environment Approval
Test
Parameters
Wave form
Acceleration amplitude
Shock
Bump duration
Converter operation
Number of bumps
Test mode
Vibration
Displacement
Acceleration
Converter operation
Conditions
Half sine wave
5gn
30 ms
Before and after test, body mounted (on chassis)
18 (3 in each direction for every axis)
Sweep sine, 10-100Hz, speed 0.05Hz/s
1 mm
3g, 3 loops 30min one cycle, 3h total, every axis tested
Before and after test, body mounted (on chassis)
Safety Specifications
Parameters
Agency approvals cULus, CE, CB Scheme
Medical Electrical Equipment
Standards
Information technology Equipment
EMI - Conducted and radiated emission
Harmonic Current Emissions
Voltage fluctuations and flicker
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
Surge Immunity
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Voltage dips, Short Interruptions Immunity
IEC\EN\UL 60601-1, 2 x MOOP, CSA-C22.2 No. 601.1-
M90
EN 60950-1:2006+A11:2009
EN55011, class B
IEC/EN 61000-3-2, Class A
IEC/EN 61000-3-3, (EN60555-3)
IEC 61000-4-2 Level 3
IEC 61000-4-3 Level 2
IEC 61000-4-4 Level 3
IEC 61000-4-5 Level 2
IEC 61000-4-6 Level 2
IEC 61000-4-8 Level 2
IEC 61000-4-11
www.aimtec.com
F 052e R7.M
Tel: +1 514 620 2722
2 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only