English
Language : 

AMEOF1-JZ Datasheet, PDF (2/3 Pages) AIMTEC – Continuous short circuit protection
O
Series AMEOF1-JZ
1 Watt | AC-DC Converter
General Specifications (continued)
Parameters
Conditions
Typical
Maximum
Units
Temperature coefficient
Cooling
Humidity
Weight
Dimensions (L x W x H)
MTBF
±0.15
Free air convection
85
7
1.38 x 0.71 x 0.43 inches 35 x 18 x 11 mm
o
>200,000 hours (MIL-HDBK -217F, Ground Benign, t=+25 C)
% / °C
% RH
g
Safety Specifications
Parameters
Meets IEC 60950-1
EN 55022, Class A & B, with external filter circuits, as referenced
IEC 61000-4-2, Contact ±4KV, Criteria B
IEC 61000-4-3, 10V/m, Criteria A, with Class B external filter, as referenced
Standards
IEC 61000-4-4, ±2KV/±4KV, Criteria B, with Class A/B external filter referenced
IEC 61000-4-5, ±1KV/±2KV, Criteria B, with Class A/B external filter referenced
IEC 61000-4-6, 10Vrms, Criteria A, with Class B external filter, as referenced
IEC 61000-4-8, 10A/m, Criteria A
IEC 61000-4-11, 0-70%, Criteria B
Pin Out Specifications*
Pin
Single
1
AC N
3
AC L
5
+V sc
7
-V sc
10
-V Output
12
+V Output
* Add capacitor between pin 5 & 7.
Application circuit below.
Dimensions
35.00
(1.38)
13 57
1.30
(0.05)
10 12
5.08
(0.20)
27.94
(1.10)
Derating*
Free Air Convection
Note:
Unit: mm (inch)
Pin diameter tolerance: ±0.10 (±0.004)
Case tolerance: ±0.50 (±0.02)
Free Air Convection at 25°C
100
80
Safe Operating Area
100% load 110-240VAC
60
Or 100-340VDC
40
20
0
- 40 - 20 0
20
55
40 60
8085 100
Ambient Temperature º C
*Power derating: -40 to -20 increase 1%/°C
www.aimtec.com
F 052e R0
100
80
Safe Operating Area
60
40
20
0
85
(70)
110
(100)
240
(340)
Input Voltage VAC (VDC)
264
(400)
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only