Environment Approval
Test
Parameters
Acceleration amplitude
Shock
Bump duration
Number of bumps
Test mode
Vibration
Displacement
Acceleration
Converter operation
Conditions
Series AMEO6-NZ
6 Watt | AC-DC / DC-DC Converter
196.1 m/s²
11 ms
Along x, y, z, once each
10 ~ 55 Hz
3 minutes / cycle
19.6 m/s²
60 minutes
Safety Specifications
Parameters
Standards
Designed to meet : IEC EN61000-4-2, EN61000-4-3, EN61000-4-4, IEC EN61000-4-5, EN61000-4-6, EN61000-4-
8, EN61000-4-11, EN 55022 class B
Pin Out Specifications
Pin
Designation
1
AC Input (L)
2
AC Input (N)
3
NC
4
No Pin
5
Common
6
+V Output
Typical Applications
L
L
Fuse
N
N
C1 C2 TVS RL
-
Device
C1
Value
Electrolytic 100 µF / 25V
Vo1
+
C2
Ceramic 0.1 µF / 50V
TVS
P6SMB7.5A (AMEO6-5S-NZ)
P6SMB16A (AMEO6-12S-NZ)
+
It is recommended that the output adds TVS (transient voltage suppressor) to protect adjacent circuits (if device fails).
Derating
100
Free Air Convection
55 º C
80
Safe Operating
60
Area
40
20
0
- 25 - 20 -10 0
20 40 55 60 80 100
Ambient Temperature º C
www.aimtec.com
F 052e R8.A
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only