English
Language : 

AMEL5-AZ-1_16 Datasheet, PDF (2/5 Pages) AIMTEC – 5 Watt | AC-DC / DC-DC Converter
Series AMEL5-AZ
5 Watt | AC-DC / DC-DC Converter
General Specifications
Parameters
Conditions
Typical
Maximum
Units
Switching frequency
66
KHz
Over load protection
Foldback
130
%
Over voltage protection
Zener Diode Clamp
Short circuit protection
Auto recovery
Operating temperature
With derating over 60ºC, see chart
Refer to model application
oC
Storage temperature
-40 to +95
oC
Maximum case temperature
100
oC
Temperature coefficient
0.02
% / oC
Cooling
Free air convection
Humidity
Non condensing
20 ~ 95
% RH
Case material
Plastic (flammability to UL 94V-0)
Weight
30
g
Dimensions (L x W x H)
51.50 x 28.00 x 17.80mm (2.03 x 1.10 x 0.70inches)
MTBF
> 400,000 hrs (MIL-HDBK -217F, t=+25oC)/Full Load
> 100,000 hrs (MIL-HDBK -217F, t=at highest operating temperature)/Full Load
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Environment Approval
Test
Parameters
Wave form
Acceleration amplitude
Shock
Bump duration
Converter operation
Number of bumps
Vibrations
Test mode
Displacement
Acceleration
Converter operation
Conditions
Half sine wave
5gn
30ms
Before and after test, body mounted (on chassis)
18 (3 in each direction for every axis)
Sweep sine, 10-100Hz, speed 0.05Hz/s
1mm
3g, 3 loops 30min one cycle, 3h total, every axis tested
Before and after test, body mounted (on chassis)
Safety Specifications
Parameters
Agency approvals
cULus for all models CE, CB (not including suffix “GAZ” models)
Information technology Equipment
IEC\EN\UL 60950-1
Information technology Equipment
EN 60950-1:2006+A11:2009
EMI - Conducted and radiated emission
EN55022, class B
Harmonic Current Emissions
IEC/EN 61000-3-2, Class A
Voltage fluctuations and flicker
IEC/EN 61000-3-3, (EN60555-3)
Standards
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
IEC 61000-4-2 Air level 3, Contact level 2
IEC 61000-4-3 Level 2
Electrical Fast Transient/Burst Immunity
IEC 61000-4-4 Level 2
Surge Immunity
IEC 61000-4-5 Level 2
RF, Conducted Disturbance Immunity
IEC 61000-4-6 Level 2
Power frequency Magnetic Field Immunity
IEC 61000-4-8
Voltage dips, Short Interruptions Immunity
IEC 61000-4-11
www.aimtec.com
F 052e R8.O
Tel: +1 514 620 2722
2 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only