English
Language : 

AMEL3-5SAZ Datasheet, PDF (2/4 Pages) AIMTEC – AC-DC Converter
Series AMEL3-AZ
3Watt | AC-DC Converter
Single Output Specifications
Parameters
Conditions
Typical
Maximum
Units
Voltage accuracy
Full load (typical)*
±5
%
Line regulation
LL-HL, Full Load
±5
%
Load regulation (single output)
0-100% load (typical)*
±5
%
Transient Recovery Time
100
µs
Transient Response Deviation
25% load step
±2
Minimum load
0
3.3V&5V with 680 μF(E/C)
300
Ripple & Noise
12V&15V with 220uF (E/C)
300
24V with 470 uF (E/C)
200
% of Vout
%
mV p-p
mV p-p
mV p-p
*Ripple & Noisemeasured at 20MHz bandwidth with 0.1μFM/C and115/230/277/480VAC(typical input) with Full Load.
Dual Output Specifications
Parameters
Conditions
Typical
Voltage accuracy
Full load
±5
Line regulation
LL-HL
±5
Load regulation
0-100% load
±5
Cross regulation
25% load change
±5
Transient Recovery Time
200
Transient Response Deviation
25% load step
±2
Minimum load
0
Ripple & Noise
5D/12D/15D with 220uF (E/C)
200
512D with 220uF (E/C)
300
*Ripple & Noisemeasured at 20MHz bandwidth with 0.1μFM/C and 115/230/277/480VAC (typical input) with Full Load.
*5D/12D/15D Model with symmetric load change and 512D Model with asymmetric load change.
Maximum
Units
%
%
%
%
µs
% of Vout
%
mV p-p
mV p-p
Isolation Specifications
Parameters
Tested I/O voltage
Isolation Resistance
Conditions
30sec
Typical
>1000
Rated
3000
Units
VAC
MΩ
General Specifications
Parameters
Conditions
Typical
Maximum
Units
Switching frequency
100
KHz
Over Load protection
Fold back
>125%
Short circuit protection
Auto recovery
Operating temperature
Storage temperature
Maximum Case temperature
See de-rating chart
-40 to +80
-40 to +85
oC
100
oC
Humidity
Non condensing
20~95
% RH
Case material
Plastic resin + Fiberglass (flammability to UL 94V-0)
Weight
21
g
Dimensions (L x W x H)
MTBF
90-305VAC
90-528VAC
1.10 x 0.90 x 0.57 inches (28.00 x 23.00 x 14.50 mm)
1.10 x 0.90 x 0.67 inches (28.00 x 23.00 x 17.00 mm)
>400 000 hrs (MIL-HDBK -217F, t=+25oC)
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load
unless otherwise specified.
Environment Approval
Parameters
Wave form: Half sine wave
Conditions
Shock
Acceleration amplitude: 5gn
Bump duration: 30 ms
Number of bumps: 18 (3 in each direction for every axis)
Converter operation before and after test, body mounted (on chassis)
Test mode: Sweep sine
10-100Hz, speed 0.05Hz/s
Vibrations
Displacement: 1mm
Acceleration: 3g
3 loops 30min one cycle, 3h total, every axis tested
Converter operation before and after test, body mounted (on chassis)
www.aimtec.com
Tel: +1 514 620 2722
F 052e R8.C
2 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only