English
Language : 

AMEL2-5SAZ Datasheet, PDF (2/4 Pages) AIMTEC – AC-DC Converter
Input Specifications
Parameters
Current (full load)
Inrush current <2ms (cold start)
Leakage current
External fuse
Input Dissipation (No Load)
Conditions
115 VAC
230 VAC
277 VAC
480VAC
115 VAC
230 VAC
277 VAC
480 VAC
Recommended slow blow type
Typical
1
≦0.5
Series AMEL2-AZ
2Watt | AC-DC Converter
Maximum
60
30
25
20
10
15
20
30
0.15
Units
mA
mA
mA
mA
A
A
A
A
mA
A
W
Single Output Specifications
Parameters
Conditions
Typical
Voltage accuracy
Full load (typical)*
±5
Line regulation
LL-HL, Full Load
±5
Load regulation (single output)
0-100% load (typical)*
±5
Transient Recovery Time
100
Transient Response Deviation
25% load step
±2
Minimum load
0
3.3V&5V with 680 μF(E/C)
300
Ripple & Noise
12V&15V with 220uF (E/C)
300
24V with 470 uF (E/C)
300
*Ripple & Noisemeasured at 20MHz bandwidth with 0.1μFM/C and 115/230/277/480VAC (typical input) withFull Load.
Maximum
Dual Output Specifications
Parameters
Conditions
Typical
Voltage accuracy
Full load
±5
Line regulation
LL-HL
±5
Load regulation
0-100% load
±5
Cross regulation
25% load change
±5
Transient Recovery Time
200
Transient Response Deviation
25% load step
±2
Minimum load
0
Ripple & Noise
5D/12D/15D with 220uF (E/C)
200
512D with 220uF (E/C)
300
*Ripple & Noisemeasured at 20MHz bandwidth with 0.1μFM/C and 115/230/277/480VAC (typical input) withFull Load.
*5D/12D/15D Model with symmetric load change and 512D Model with asymmetric load change.
Maximum
Isolation Specifications
Parameters
Tested I/O voltage
Isolation Resistance
Conditions
30sec
Typical
>1000
Rated
3000
Units
%
%
%
µs
% of Vout
%
mV p-p
mV p-p
mV p-p
Units
%
%
%
%
µs
% of Vout
%
mV p-p
mV p-p
Units
VAC
MΩ
General Specifications
Parameters
Conditions
Typical
Maximum
Units
Switching frequency
100
KHz
Over Load protection
Fold back
>125%
Short circuit protection
Operating temperature
Storage temperature
Maximum Case temperature
See de-rating chart
Auto recovery
-40 to +80
oC
-40 to +85
oC
100
oC
Humidity
Non condensing
20~95
% RH
Case material
Plastic resin + Fiberglass (flammability to UL 94V-0)
Weight
21
g
Dimensions (L x W x H)
MTBF
90-305VAC
90-528VAC
1.10 x 0.90 x 0.57 inches (28.00 x 23.00 x 14.50 mm)
1.10 x 0.90 x 0.67 inches (28.00 x 23.00 x 17.00 mm)
>400 000 hrs (MIL-HDBK -217F, t=+25oC)
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load
unless otherwise specified.
www.aimtec.com
F 052e R8.C
Tel: +1 514 620 2722
2 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only