General Specifications
Parameters
Conditions
Typical
Maximum Units
Switching frequency
66
KHz
Over load protection
Auto recovery, Fold back
150
%
Over voltage protection
Zener Diode Clamp
Short circuit protection
Operating temperature
Maximum case temperature
Storage temperature
Temperature coefficient
With derating above 50ºC
Auto recovery
-40 to +80
-45 to +95
±0.02
oC
100
oC
oC
% / oC
Humidity
Non condensing
20 ~ 95
% RH
Case material
Plastic resin + Fiberglass (flammability to UL 94V-0)
Weight
70
g
Dimensions (L x W x H)
MTBF
2.22 x 1.21 x 0.99 inches 56.48 x 30.86 x 25.10mm
> 400 000 hrs (MIL-HDBK -217F, t=+25oC)
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Environment Approval
Test
Parameters
Wave form
Acceleration amplitude
Shock
Bump duration
Converter operation
Number of bumps
Test mode
Vibration
Displacement
Acceleration
Converter operation
Conditions
Half sine wave
5gn
30 ms
before and after test, body mounted (on chassis)
18 (3 in each direction for every axis)
Sweep sine
1mm
3g
10-100Hz, speed 0.05Hz/s
Safety Specifications
Parameters
Standards
Information technology Equipment
EMI - Conducted and radiated emission
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
Surge Immunity
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Voltage dips, Short Interruptions Immunity
Information Technology Equipment
Information Technology Equipment
EN 60950-1:2006+A11:2009
EN55011, class B
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-11
UL 60950-1:2007
CAN/CSA-C22.2 No.60950-1-07