English
Language : 

AME5-CJZ Datasheet, PDF (2/5 Pages) AIMTEC – Continuous Short circuit protection
Input Specifications
Parameters
Current (full load)
Inrush current <2ms (cold start)
Leakage current
External fuse
Conditions
115 VAC
230 VAC
115 VAC
230 VAC
230VAC/50Hz
Recommended slow blow type
Series AME5-CJZ
5 Watt | AC-DC / DC-DC Converter
Typical
10
20
1
Maximum
125
80
0.3
Units
mA
mA
A
A
mA
A
Output Specifications
Parameters
Voltage accuracy
Line regulation
Load regulation (single output)
Load Regulation (dual output)
Load Regulation (triple &
asymmetric separated output)
Minimum load
Ripple & Noise *
Hold-up time
Conditions
Full load, main output
Full load, auxiliary output
10-100% load
10-100% Balanced load
10-100% Balanced load, main output
10-100% Balanced load, auxiliary output
Single output
Others
115VAC, 20MHz bandwidth
230VAC, 20MHz bandwidth
Typical
±2
±0.5
±1.5
±1
±2
±3
±5
0
10
50
15
80
Maximum
Units
%
%
%
%
%
%
%
150
mV p-p
ms
ms
Isolation Specifications
Parameters
Tested I/O voltage
Isolation voltage between Main and Auxiliary output
Isolation Resistance
Conditions
60 sec
60 sec
Typical
>1000
Rated
3000
500
Units
VAC
VDC
MΩ
General Specifications
Parameters
Conditions
Typical
Maximum
Units
Switching frequency
Single and asymmetrical dual output
Dual and triple output
65
140
KHz
Protection class
Class I
Over current protection
≥110
% of Iout
Over voltage protection
Zener diode clamp
Short circuit protection
Operating temperature
Storage temperature
Maximum Case temperature
Temperature coefficient
See derating curve
Continuous, Auto recovery
-25 to +70
-25 to +105
100
±0.02
oC
oC
oC
% / oC
Cooling
Free air convection
Humidity
Non condensing
95
% RH
Case material
Plastic (flammability to UL 94V-0)
Weight
50
g
Dimensions (L x W x H)
MTBF
1.91 x 1.42 x 0.81 inches 48.5 x 36 x 20.5 mm
> 300,000 hrs (MIL-HDBK -217F, t=+25oC)/Full Load
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
www.aimtec.com
F 052e R8
Tel: +1 514 620 2722
2 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only