English
Language : 

AME40-CJZ Datasheet, PDF (2/7 Pages) AIMTEC – 40 Watt | AC-DC / DC-DC Converter
Output Specifications (continued)
Parameters
Load regulation (single output)
Load Regulation (dual output)
Conditions
0-100% load
10-100% Balanced load
Load Regulation (asymmetric
separated output)
Cross regulation (dual output)
25-100% Balanced load, main output
25-100% Balanced load, auxiliary output
Cross regulation (asymmetric
separated output)
Ripple & Noise
Hold-up time
Voltage adjustment range
Main output
Auxiliary output
115VAC, 20MHz bandwidth
230VAC, 20MHz bandwidth
Single output only
Series AME40-CJZ
40 Watt | AC-DC / DC-DC Converter
Typical
±1
±2
±2
±5
±5
±1
±7
50
15
80
Maximum
±8
100
±10
Units
%
%
%
%
%
%
%
mV p-p
ms
ms
% of Vout
Isolation Specifications
Parameters
Tested I/O voltage
Isolation voltage between Main and Auxiliary
output
Isolation Resistance
Conditions
60 sec
60 sec
Typical
>1000
Rated
3000
500
Units
VAC
VAC
MΩ
General Specifications
Parameters
Conditions
Typical
Maximum
Units
Switching frequency
100% load
65
KHz
Protection class
Class II
Over current protection
≥110
% of Iout
Over voltage protection
Zener diode clamp
Short circuit protection
Continuous, Auto recovery
Operating temperature
See derating curve
-40 to +70
oC
Storage temperature
-40 to +85
oC
Maximum Case temperature
100
oC
Temperature coefficient
±0.02
% / oC
Cooling
Free air convection
Humidity
Non condensing
95
% RH
Case material
Plastic (flammability to UL 94V-0)
Weight
225
g
Dimensions (L x W x H)
3.5 x 2.5 x 0.98 inches 89.0 x 63.5 x 25.0 mm
MTBF
> 300,000 hrs (MIL-HDBK -217F, t=+25oC)/Full Load
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Safety Specifications
Parameters
Agency approvals
cULus, CE (single output models only)
Information technology Equipment
EMI - Conducted and radiated emission
Standards
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
Surge Immunity
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Voltage dips, Short Interruptions Immunity
IEC/EN/UL 60950-1
EN55022, class B
IEC 61000-4-2 Level 3
IEC 61000-4-3 Level 3
IEC 61000-4-4 Level 3
IEC 61000-4-5 Level 3
IEC 61000-4-6 Level 3
IEC 61000-4-8 Level 3
IEC 61000-4-11 Class 2
www.aimtec.com
F 052e R8.A
Tel: +1 514 620 2722
6832)
2 of 7
Toll free: + 1 888 9 AIMTEC (924
North America only