English
Language : 

AME30 Datasheet, PDF (2/3 Pages) AIMTEC – 30 watt encapsulated ac-dc converter
AME30 Series
30 watt encapsulated ac-dc converter
ELECTRICAL SPECIFICATIONS
All specifications valid at nominal Input voltage, full load and +25°C after warm-up time unless otherwise stated.
Model No. (Dual & Triple Output)
AME30-5D AME30-12D AME30-15D AME30-5S12S AME30-512T AME30-515T
Max output wattage (W)
30W
30W
30W
30W
30W
30W
Voltage
90 ... 260 VAC or 120 ... 370 VDC
Frequency (Hz)
47 ... 440 Hz
Current (Full Load)
520mA max. (115 VAC) / 320mA max. (230 VAC)
Input
Inrush Current (<2ms)
10 A max. (115 VAC) / 20 A max. (230VAC)
Leakage Current
0.75mA max.
External Fuse (recommended)
1.5 A slow blow type
Voltage (VDC)
±5V
±12V
±15V
5/12V 5/±12V 5/±15V
Voltage Accuracy
±2%
Current (mA) max.
±3000 ±1250 ±1000 3000/1250 3000/±630 3000/±500
Line Regulation (typ.)
±1%
±1%
±1% ±1%/±5% ±1%/±5% ±1%/±5%
Load Regulation (typ.)
±3%
±3%
±3% ±3%/±6% ±2%/±6% ±2%/±6%
Output Minimum Load
2%
3%
1%
20%
20%
20%
Maximum Capacitive Load
Noise
470-23,000m F depending on model
<0.5% Vout +50mV max (Vp-p)
Ripple
<0.2% Vout +40mV max (Vp-p)
Efficiency
80%
84%
84%
80%
80%
80%
Hold-up Time
15 ms min.
Switching Frequency
100 kHz
Over Current Protection
Hiccup technique, auto-recovery
Protection Over Voltage Protection
Zener diode clamp
Short Circuit Protection
Hiccup mode, indefinite (automatic recovery)
Isolation Input-Output (VAC)
3000V
Operating Temperature
-25°C ... +71°C
Storage Temperature
-40°C ... +85°C
Environment Temperature Coefficient
0.02% / °C
Humidity
95% RH
MTBF
>190,000 h @ 25°C (MIL-HDBK-217F)
Dimension (L x W x H)
3.5 x 2.5 x 0.98 inches (89.0 x 63.5 x 25.0 mm)
Physical
Case Material
Weight
Plastic resin + Fiberglass (flammability to UL 94V-0)
220g
Cooling Method
Free air convection
Safety Agency Approvals
cUL, CE
EMC
EMI (Conducted & Radiated Emission)
EMS (Noise Immunity)
EN 55022 class B
EN 55024
Specifications are subject to change without notification
Note:
1. The triple output required a minimum 20% loading on the ouput to maintain specified regulation. Operation under no-load condition
will not damage these devices, however they may not meet all listed specifications.
2. Load regulation for triple output:
Main output (V1): 20% to 100% with 20% to 100% balanced on auxiliaries.
Auxiliary outputs (V2 abd V3): 20% to 100% balanced on all outputs.
3. Cross regulation for triple output:
Main output 100% load, auxiliary 100%, other auxiliary 25% to 100%.
Auxiliary outputs (V2 and V3): Main output 100% load, auxiliary 100%, other auxiliary 25% to 100% or main output 25%, auxiliary 25%,
other auxiliary 25% to 100%
103
Continued on next page
VISIT US AT WWW.AIMTEC.CA