General Specifications (continued)
Parameters
Storage temperature
Maximum Case temperature
Conditions
Typical
-40 to +85
Maximum
100
Units
oC
oC
Humidity
Non condensing
20 ~ 95
% RH
Case material
Plastic resin + Fiberglass (flammability to UL 94V-0)
Weight
25
g
Dimensions (L x W x H)
MTBF
1.327 x 0.874 x 0.71 (33.70 x 22.20 x 18.00mm)
> 400 000 hrs (MIL-HDBK -217F, t=+25oC)
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load
unless otherwise specified.
Environment Approval
Parameters
Conditions
Wave form: Half sine wave
Acceleration amplitude: 5gn
Shock
Bump duration: 30 ms
Number of bumps: 18 (3 in each direction for every axis)
Converter operation before and after test, body mounted (on chassis)
Test mode: Sweep sine
10-100Hz, speed 0.05Hz/s
Vibrations
Displacement: 1mm
Acceleration: 3g
3 loops 30min one cycle, 3h total, every axis tested
Converter operation before and after test, body mounted (on chassis)
Safety Specifications
Parameters
Agency approvals
cULus, CE, CB (pending), CSA
Information technology Equipment
EMI - Conducted and radiated emission
Harmonic Current Emissions
Voltage fluctuations and flicker
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
Surge Immunity (1KV)
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Voltage dips, Short Interruptions Immunity
Canadian Safety Agency
IEC/EN/UL 60950-1:2006+A11:2009
EN55022, class B
IEC/EN 61000-3-2, (EN60555-2)
IEC/EN 61000-3-3, (EN60555-3)
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5(SAZ:Level2,SBAZ:Level 1)
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-11
CAN/CSA-C22.2 NO. 60950-1-07
Derating
Free Air Convection
70 ºC
100
80
60
Safe Operating Area
40
20
0
70
-40 -20
0
20
40 60 80
Ambient Temperature º C