AME05 Series
5 watt encapsulated ac-dc converter
ELECTRICAL SPECIFICATIONS
All specifications valid at nominal Input voltage, full load and +25°C after warm-up time unless otherwise stated.
Model No. (Dual Output)
AME05-5D
AME05-12D
AME05-15D
Max output wattage (W)
Voltage
5W
5W
5W
90 ... 260 VAC or 120 ... 370 VDC
Frequency (Hz)
47 ... 440 Hz
Current (Full Load)
110mA max. (115 VAC) / 70mA max. (230 VAC)
Input
Inrush Current (<2ms)
10 A max. (115 VAC) / 20 A max. (230VAC)
Leakage Current
0.75mA max.
External Fuse (recommended)
1.5 A slow blow type
Voltage (VDC)
±5V
±12V
±15V
Voltage Accuracy
±2%
Current (mA) max.
±500
±200
±160
Line Regulation (typ.)
±0.3%
Load Regulation (typ.)
±0.5%
Output
Minimum Load
Maximum Capacitive Load
Noise
0%
0%
3%
470-23,000m F depending on model
<0.5% Vout +50mV max (Vp-p)
Ripple
<0.2% Vout +40mV max (Vp-p)
Efficiency
72%
75%
75%
Hold-up Time
15 ms min.
Switching Frequency
100 kHz
Over Current Protection
Hiccup technique, auto-recovery
Protection Over Voltage Protection
Zener diode clamp
Short Circuit Protection
Hiccup mode, indefinite (automatic recovery)
Input-Output (VAC)
3000V
Isolation Input-FG (VAC)
1500V
Outut-FG (VAC)
500V
Operating Temperature
-25°C ... +71°C
Storage Temperature
Environment Temperature Coefficient
-40°C ... +85°C
0.02% / °C
Humidity
95% RH
MTBF
>290,000 h @ 25°C (MIL-HDBK-217F)
Dimension (L x W x H)
2.17 x 1.77 x 0.81 inches (55.0 x 45.0 x 20.5 mm)
Physical
Case Material
Weight
Plastic resin + Fiberglass (flammability to UL 94V-0)
80g
Cooling Method
Free air convection
Safety Agency Approvals
cUL, CE
EMC
EMI (Conducted & Radiated Emission)
EMS (Noise Immunity)
EN 55022 class B
EN 50082-1
Specifications are subject to change without notification
94