Series AM30E-Z
30Watt | DC-DC Converter
Input Specifications (continued)
Parameters
Nominal
Typical
Maximum
Units
Peak Input Voltage time
100
ms
On/Off control
ON: 3 ~12VDC or open circuit ; OFF - 0 ~ 1.2VDC or Short circuit between pin 2 and pin 3
12V ON/OFF
8.6 / 7.9
Under voltage lockout
24V ON/OFF
17.8 / 16
VDC
48V ON/OFF
33.5 / 30.5
Isolation Specifications
Parameters
Tested I/O voltage
Case/Input tested voltage
Resistance
Capacitance
Conditions
3 sec
3 sec
Typical
1600
1000
1500
Rated
1600
Units
VDC
VDC
MOhm
pF
Output Specifications
Parameters
Voltage accuracy
Cross Regulation (Dual Output Models)
Over voltage protection
Over current protection
Short Circuit protection
Short circuit restart
Thermal shutdown
Line voltage regulation
Load voltage regulation (Single)
Load voltage regulation (Dual)
Temperature coefficient
Ripple & Noise
Voltage adjustment range (single)
Minimum Load Current
Conditions
25% load on one output
100% load on second load
On Case
HL-LL
0 – 100% load
0 – 100% load
20MHz Bandwidth
Typical
±1
±5
Zener diode clamp
150
Continuous
Auto-Recovery
115
±0.5
±0.5
±1
±0.02
100
±10
0
Maximum
Units
%
%
%
ºC
%
%
%
%/oC
mV p-p
%
% of Max
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Maximum case temperature
Derating
Cooling
Humidity
Case material
Weight
Dimensions (L x W x H)
MTBF
Maximum soldering temperature
Transient recovery time
Transient recovery deviation
Conditions
Typical
Maximum
100% load
330
Derating above 50
-40 to +75
-40 to +125
105
2
Free Air Convection
95
Nickel coated Copper
31
2.00 x 1.00 x 0.40 inches 50.80 x 25.40 x 10.16 mm
>435,000 hrs (MIL-HDBK -217F, Ground Benign, t=+25ºC)hours
1.5mm from case for 10 sec
260
250
±3
Units
KHz
oC
oC
oC
%/ oC
% RH
g
oC
mS
%
Safety Specifications
Parameters
Agency Approvals
CE
EN55022 Class A
Standards
IEC61000-4-2, Perf. Criteria B
IEC61000-4-3, Perf. Criteria A
IEC61000-4-4, Perf. Criteria A (external 220uF/100V cap required)
www.aimtec.com
Tel: +1 514 620 2722
F 051e R12.E
2 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only