English
Language : 

AM1L-N-Z Datasheet, PDF (2/7 Pages) AIMTEC – 1 Watt | DC-DC Converter
Models
Dual Separated Output
Model
Input
Voltage (V)
Output Voltage
(V)
Output Current Max |
Min (mA)
AM1L-050505D-NZ
4.5-5.5
5/5
100/100
10/10
*AM1L-051212D-NZ
4.5-5.5
12/12
42/42
4/4
*AM1L-051515D-NZ
4.5-5.5
15/15
33/33
3/3
AM1L-121212D-NZ
10.8-13.2
12/12
42/42
4/4
*Not recommended for new design
NOTE 1: Add suffix “TR” to a part number when ordering in tape and reel package
Series AM1L-NZ
1 Watt | DC-DC Converter
Isolation
(VDC)
1000
1000
1000
1000
Efficiency
(%)
70
79
80
78
NOTE 2: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified
Input Specifications
Parameters
Voltage range
Filter
Nominal
3
5
12
24
Typical
3.0-3.6
4.5-5.5
10.8-13.2
21.6-26.4
Maximum
Capacitor
Units
VDC
Isolation Specifications
Parameters
Tested I/O voltage
Tested V1 output/ V2 output
Capacitance V input/V output
Capacitance V1 output/V2 output
Resistance
Conditions
60 sec
60 sec
500Vdc
500Vdc
500Vdc
Typical
1000
60
60
> 1000
Rated
1000 & 3000
Units
VDC
VDC
pF
pF
MOhm
Output Specifications
Parameters
Conditions
Typical
Maximum
Units
Voltage accuracy
See the tolerance graph
±5
%
Voltage balance
Dual Output
±2
%
Short Circuit protection
Momentary (1sec)
Line voltage regulation (Single)
For 1.0% of Vin
±1.2
%
Line voltage regulation (Dual)
For 1.0% of Vin
±1.2
%
Line voltage regulation (Dual Separated)
For 1.0% of Vin
±1.2
%
Load voltage regulation (Single)
Load 10 – 100%
10
%
Load voltage regulation (Dual)
Load 10 – 100%
10
%
Load voltage regulation (Dual Separated)
Temperature coefficient
Load 10 – 100%
12.8
±0.03
%
%/oC
Ripple & Noise
At 20MHz Bandwidth
75
100
mV p-p
If the operating output current is less than 10% of maximum it is recommended to install a load resistor in parallel with the
load to ensure the actual load current meets the minimum load current requirement.
General Specifications
Parameters
Switching frequency
Max Case temperature
Operating temperature
Storage temperature
Cooling
Conditions
100% load
Without derating
Typical
Maximum
100
+95
-40 to +85
-55 to +125
Free air convection
Units
KHz
oC
oC
oC
www.aimtec.com
F 051e R8.O
Tel: +1 514 620 2722
2 of 7
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only