English
Language : 

AM15E-IZ Datasheet, PDF (2/5 Pages) AIMTEC – 15 Watt | DC-DC Converter
Models
Dual output (continued)
Input
Model
Voltage
(V)
AM15E-2405DH30IZ
18-36
AM15E-2412DH30IZ
18-36
AM15E-2415DH30IZ
18-36
AM15E-4805DH30IZ
36-75
AM15E-4812DH30IZ
36-75
AM15E-4815DH30IZ
36-75
Series AM15E-IZ
15 Watt | DC-DC Converter
Output
Voltage
(V)
±5
±12
±15
±5
±12
±15
Output Current
max (A)
±1.5
±0.62
±0.5
±1.5
±0.62
±0.5
Ripple & Noise
typ
50mVp-p
120mVp-p
150mVp-p
50mVp-p
120mVp-p
150mVp-p
Isolation
(VDC)
3000
3000
3000
3000
3000
3000
Efficiency
(%)
80
82
84
76
83
85
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load
unless otherwise specified.
Input Specifications
Parameters
Voltage range
Filter
Remote On/Off Control
Absolute Maximum Rating
Permissible absolute maximum duration
Recommended Input Fuse (slow blow)
Nominal
12
24
48
On
Off
12 Vin
24 Vin
48 Vin
12 Vin
24 Vin
48 Vin
Typical
Maximum
Units
9-18
18-36
VDC
37-75
π (Pi) Network
3.5 to 12VDC or open circuit
0 to 1.2VDC or short circuit between pin 2 and 4; typical idle current 3mA
25
50
VDC
100
2
h
4A/250V
2A/250V
1A/250V
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Capacitance
Conditions
3 sec
Typical
1500 & 3000
> 1000
1000
Maximum
Units
VDC
MOhm
pF
Output Specifications
Parameters
Voltage accuracy
Short Circuit protection
Short Circuit restart
Over voltage protection
Over load protection
Line voltage regulation (Single)
Line voltage regulation (Dual)
Load voltage regulation (Single)
Load voltage regulation (Dual)
Temperature coefficient
Transient response recovery time
Conditions
HL-LL
HL-LL
25-100%
25-100%
25% load step
change
Typical
Maximum
±2
Continuous
Auto recovery
Zener diode clamp protection
Over 110% full load with auto-recovery
±0.5
±0.5
±0.5
±2
±0.05
300
Units
%
%
%
%
%
%/oC
uS
www.aimtec.com
F 051e R12.C
Tel: +1 514 620 2722
2 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only