English
Language : 

AM15CW-Z Datasheet, PDF (2/4 Pages) AIMTEC – 15Watt | DC-DC Converter
Isolation Specifications
Parameters
Tested I/O voltage
Case to Input
Case to Output
Resistance
Capacitance
Conditions
3 sec
3 sec
3 sec
Series AM15CW-Z
15Watt | DC-DC Converter
Typical
1600
1600
1600
>1000
Maximum
1200
Units
VDC
VDC
VDC
MOhm
pF
Output Specifications
Parameters
Voltage accuracy
Cross Regulation (Dual Output Models)
Over voltage protection
Over current protection
Short Circuit protection
Short circuit restart
Line voltage regulation
Load voltage regulation (Single)
Load voltage regulation (Dual)
Temperature coefficient
Ripple & Noise
Voltage adjustment range
Conditions
25% load on one output - 100% load
on second load
Zener Diode Clamp
Full Load
HL-LL
0% to 100% load
0% to 100% balanced load
20MHz Bandwidth
Trim - Single output models only
Typical
±1
±5
120
170
Continuous
Auto-Recovery
±0.2
±0.5
±1
±0.02
100
10
Maximum
Units
%
%
%
%
%
%
%
%/oC
mV p-p
%
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Maximum case temperature
Derating
Cooling
Humidity
Case material
Weight
Dimensions (L x W x H)
MTBF
Maximum soldering temperature
Transient recovery time
Transient recovery deviation
Conditions
Typical
Maximum
100% load
375
With derating above +55°C
-40 to +85
-40 to +125
100
2.6
Free air convection
95
Nickel-coated copper
18
1.00 x 1.00 x 0.40 inches 25.40 x 25.40 x 10.16 mm
> 560,000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC)
1.5mm from case for 10 sec
260
Load step change 75% to 50% to 25%
250
Load step change 75% to 50% to 25%
±3
Units
KHz
oC
oC
oC
%/ oC
% RH
g
oC
µS
%
Safety Specifications
Parameters
Agency Approvals
CE
Standards
EN 55022 Class A
EN 61000-4-2 Perf. Criteria A
EN 61000-4-3 Perf. Criteria A
EN 61000-4-4 Perf. Criteria A (external 220uF/100V cap required)
EN 61000-4-5 Perf. Criteria A (external 220uF/100V cap required)
EN 61000-4-6 Perf. Criteria A
EN 61000-4-8 Perf. Criteria A
NOTE: also designed to meet IEC/EN 60950-1
www.aimtec.com
F 051e R11
Tel: +1 514 620 2722
2 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only