English
Language : 

AM12TW-Z_13 Datasheet, PDF (2/4 Pages) AIMTEC – 12 Watt | DC-DC Converter
Isolation Specifications
Parameters
Tested I/O voltage
Tested Case/Input and Output
Resistance
Capacitance
Output Specifications
Parameters
Voltage accuracy
Voltage balance
Line voltage regulation
Load voltage regulation (Single)
Load voltage regulation (Dual)
Over voltage protection
Over current protection
Short Circuit protection
Short circuit restart
Temperature coefficient
Ripple & Noise
Conditions
3 sec
Conditions
Dual output
HL-LL
0% Load to Full Load
0% Load to Full Load
Full Load
Series AM12TW-Z
12 Watt | DC-DC Converter
Typical
1600
>1000
1500
Typical
±1.2
±5
±0.2
±0.5
±1.0
Zener diode clamp
170
Continuous
Auto recovery
±0.02
85
Rated
1600
Maximum
Units
VDC
VDC
MOhm
pF
Units
%
%
%
%
%
%
%/oC
m Vp-p
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Max Case temperature
Derating
Cooling
Humidity
Case material
Weight
Dimensions (L x W x H)
MTBF
Conditions
Typical
Maximum
Units
100% load
270
KHz
Full Load with derating above 60ºC
-40 to +85
oC
-40 to +125
oC
105
oC
Above 60ºC
2.5 % per 1ºC
Free air convection
95
% RH
Nickel-coated Copper
18.0
g
Tolerance ±0.5 mm or ±0.02 inches
1.25 x 0.8 x 0.40 inches 31.75 x 20.32 x 10.16 mm
>1 000 000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC)
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input
voltage and at rated output load unless otherwise specified
Safety Specifications
Parameters
Agency Approval
Standards
CE
EN55022 Class A, EN55024
IEC61000-4-2, Perf. Criteria B
IEC61000-4-3, Perf. Criteria A
IEC61000-4-4, Perf. Criteria B (external 330uF/100V cap required)
IEC61000-4-5, Perf. Criteria B (external 330uF/100V cap required)
IEC61000-4-6, Perf. Criteria A
IEC61000-4-8, Perf. Criteria A
Note: also meets IEC 60950-1:2001
www.aimtec.com
F 051e R12.C
Tel: +1 514 620 2722
2 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only