English
Language : 

AM12T-Z Datasheet, PDF (2/3 Pages) AIMTEC – 12 Watt | DC-DC Converter
Input Specifications (continued)
Parameters
Peak Input Voltage time
Input reflected ripple current
Quiescent Current
On/Off Control
Series AM12T-Z
12 Watt | DC-DC Converter
Nominal
Typical
Maximum
1000
20
15
ON – High (3.0 ... 12Vdc) or open circuit;
OFF – Low (0 ... 1.2Vdc) or Short circuit pin1 and pin 2/3
OFF idle current: 5.0 mA typ
Units
ms
mA p-p
mA
Isolation Specifications
Parameters
Tested I/O voltage
Tested Case/Input and Output
Resistance
Capacitance
Conditions
3 sec
Typical
1600
>1000
1200
Rated
1600
Units
VDC
VDC
MOhm
pF
Output Specifications
Parameters
Voltage accuracy
Voltage balance
Line voltage regulation
Load voltage regulation (Single)
Load voltage regulation (Dual)
Over voltage protection
Over current protection
Short Circuit protection
Short circuit restart
Ripple & Noise
Conditions
Dual output
HL-LL
0% Load to Full Load
0% Load to Full Load
Full Load
Typical
±1.2
±5
±0.5
±0.5
±1.0
Zener diode clamp
150
Continuous
Auto recovery
85
Maximum
Units
%
%
%
%
%
%
m Vp-p
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Max Case temperature
Temperature coefficient
Derating
Cooling
Humidity
Case material
Potting material
Weight
Dimensions (L x W x H)
MTBF
Conditions
Typical
Maximum
Units
100% load
Full Load with Derating above 60ºC
330
-40 to +85
-40 to +125
100
±0.02
KHz
oC
oC
oC
%/oC
Above 60ºC
2.5 % per 1ºC
Free air convection
95
% RH
Nickel-coated Copper
UL94V-0 rated
18.0
g
Tolerance ±0.5 mm or ±0.02 inches
1.25 x 0.80 x 0.40 inches 31.80 x 20.30 x 10.20 mm
>1 000 000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC)
Safety Specifications
Parameters
Agency Approval
Standards
CE
IEC 60950-1:2005 (2nd Edition); EN 60950-1: 2006
EN55022 Class A, EN55024
IEC61000-4-2, Perf. Criteria B
IEC61000-4-3, Perf. Criteria A
IEC61000-4-4, Perf. Criteria B (external 330uF/100V cap required)
IEC61000-4-5, Perf. Criteria B (external 330uF/100V cap required)
IEC61000-4-6, Perf. Criteria A
IEC61000-4-8, Perf. Criteria A
www.aimtec.com
F 051e R12.F
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only