Output Specifications
Parameters
Voltage accuracy
Cross Regulation (Dual Output Models)
Over voltage protection
Over current protection
Short Circuit protection
Short circuit restart
Line voltage regulation
Load voltage regulation (Single)
Load voltage regulation (Dual)
Temperature coefficient
Ripple & Noise
Minimum Load Current
Conditions
25% load on one output
100% load on second load
Full Load
HL-LL
0% Load to Full Load
0% Load to Full Load
20MHz Bandwidth
Series AM10TW-Z
10 Watt | DC-DC Converter
Typical
±1.2
±5
Zener diode clamp
170
Continuous
Auto recovery
±2
±0.5
±1.0
±0.02
85
0
Maximum
Units
%
%
%
%
%
%
%/oC
mV p-p
% of Max
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Maximum case temperature
Derating
Cooling
Humidity
Case material
Potting material
Weight
Dimensions (L x W x H)
MTBF
Maximum soldering temperature
Transient recovery time
Transient recovery deviation
Conditions
Typical
Maximum
100% load
270
Full Load with derating above 60ºC
-40 to +85
-40 to +125
105
Above 60ºC
2.5
Free air convection
95
Nickel-coated Copper
UL94V-0 rated
18
1.25 x 0.80 x 0.40 inches 31.75 x 20.32 x 10.16 mm
>1 000 000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC)
1.5mm from case for 10 sec
260
250
±3
Units
KHz
oC
oC
oC
%/ oC
% RH
g
oC
uS
%
Safety Specifications
Parameters
Agency approvals
CE
EN55022 Class A
IEC61000-4-2, Perf. Criteria B
IEC61000-4-3, Perf. Criteria A
Standards
IEC61000-4-4, Perf. Criteria B (external 330uF/100V cap required)
IEC61000-4-5, Perf. Criteria B (external 330uF/100V cap required)
IEC61000-4-6, Perf. Criteria A
IEC61000-4-8, Perf. Criteria A
NOTE: Also designed to meet standard IEC 60950-1: 2001
Pin Out Specifications
Pin
Single
Dual
1 Remote On/Off Remote On/Off
2
-V Input
-V Input
3
-V Input
-V Input
9
No Pin
Common
11
N.C.
-V Output
14
+V Output
+V Output
16
-V Output
Common
22
+V Input
+V Input
23
+V Input
+V Input
www.aimtec.com
F 051e R12.C
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)