AMER90C-50180AZ Datasheet, PDF (1/6 Pages) AIMTEC – LED Driver / Converter
FEATURES:
Click on Series name for product info on aimtec.com
Series AMER90C-CAZ
up to 3.75A | AC-DC / DC-DC | LED Driver / Converter
• Constant current LED Driver or Converter • Over Temperature Protection
• Input range 90-305VAC/47-440Hz
• Waterproof Case rated IP68
• High Efficiency up to 91%
• Power Factor Correction
• 115VAC Operating temperature -50 to 85°C • Short Circuit Protection
• 230VAC Operating temperature -55 to 85°C • Over Current Protection
Models
Single output
• Dimmable via resistive / 0-10Vdc / PWM
• 5 Years Limited Warranty
Model
Max
Output
Power
(W)①
Output
Voltage
Range
(V)③
Output
Current
(A)③
Input
Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Mode of Operation
Efficiency
(%)
115 230 277
VAC
VAC
VAC
AMER90C-50180CAZ
90
36-50
1.8
90-305/47-
440
130-430
Constant Current
87 86 86
Constant Voltage② 88 87 87
AMER90C-36250CAZ
90
24-36
2.5
90-305/47-
440
130-430
Constant Current
87 87 87
Constant Voltage② 88 87 87
AMER90C-24375CAZ
90
12-24
3.75
90-305/47-
440
130-430
Constant Current
86 86 86
Constant Voltage② 87 86 86
①Exceeding the maximum output power will permanently damage the converter.
②The dimming feature is not supported when units are used in Constant Voltage mode only,
③In constant current mode output current is maximum shown, in constant voltage mode output voltage is the maximum shown. All
models can be ordered with optional North American colour input wires (black (L), white (N), green (GND)). Add “–NA” to part number
when ordering.
NOTE: Aimtec limited warranty of 5 years is valid based on product operation at datasheet specifications at ambient temperature of 25°C,
humidity<75%, nominal input voltage (115/230/277VAC) and at rated output load unless otherwise specified.
See http://www.aimtec.com/terms-sale
AMER90C-CAZ’s AC/DC LED drivers have electrical safeguards designed within to protect it from conventional electrical abnormalities with
the levels listed in the safety table. Applications for use within rural agricultural, heavy industrial, and other areas or regions which are
prone to ‘dirty’ electrical conditions which would subject any of the above models to excessive voltages surges or spikes, may damage or
cause early life failure of product. In this case consideration should be made by the end user to ensure that adequate line or mains surge
suppression is installed in front of Aimtec device to ensure the longevity of the products. Failure to identify excessive line surges violations
prior to installation may damage sensitive equipment permanently.
Input Specifications
Parameters
Current (full load)
Inrush current <2ms(cold start)
Leakage current
Power factor
External fuse
Start-up time
Conditions
115 VAC
230 VAC
277 VAC
115 VAC
230 VAC
277 VAC
I/O
I/FG, O/FG
115 VAC
230 VAC
277 VAC
Recommended slow blow type
Typical
0.98
0.94
0.90
2.5
1000
Maximum
1500
600
500
40
50
60
0.25
3.5
Units
mA
mA
mA
A
A
A
mA
mA
A
ms
www.aimtec.com
F 052.1e R3.B
Tel: +1 514 620 2722
1 of 6
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only