English
Language : 

AMER90-AZ_16 Datasheet, PDF (1/11 Pages) AIMTEC – AC-DC Constant Current or Constant Voltage LED Driver
Click on Series name for product info on aimtec.com
Series AMER90-AZ
up to 3.75A | AC-DC / DC-DC | LED Driver / Converter
FEATURES:
Models
Single output
 AC-DC Constant Current or Constant
Voltage LED Driver
 Input range 90-305VAC/47-440Hz
 High Efficiency up to 88%
 Operating temperature -40 to 85°C
 Dimmable via resistive
 5 Years Limited Warranty
 Over Temperature Protection
 Over Current Protection
 Waterproof Case rated IP68
 Power Factor Correction
 Short Circuit Protection
Model
Max
Output
Power
(W)①
Output
Voltage
Range
(V)③
Output
Current
(A)③
Input
Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Mode of Operation
Efficiency
(%)
115 230 277
VAC
VAC
VAC
AMER90-50180AZ
90
36-50
1.8
90-305/47-440 130-430
Constant Current
87 86 86
Constant Voltage② 88 87 87
AMER90-36250AZ
90
24-36
2.5
90-305/47-440 130-430
Constant Current
87 87 87
Constant Voltage② 88 87 87
AMER90-24375AZ
90
12-24
Constant Current
86 86 86
3.75
90-305/47-440 130-430
Constant Voltage② 87 86 86
Add suffix “-F”
No dimming option
①Exceeding the maximum output power will permanently damage the converter.
②The dimming feature is not supported when units are used in Constant Voltage mode only, Aimtec suggests to order “-F” No
dimming option in the case.
③ In constant current mode output current is maximum shown, in constant voltage mode output voltage is the maximum shown. All
models can be ordered with optional North American colour input wires (black (L), white (N), green (GND)). Add “–NA” to part number
when ordering.
NOTE: Aimtec limited warranty of 5 years is valid based on product operation at datasheet specifications at ambient temperature of 25°C,
humidity<75%, nominal input voltage (115/230/277VAC) and at rated output load unless otherwise specified. See
http://www.aimtec.com/terms-saleAMER90-AZ’s AC/DC LED drivers have electrical safeguards designed within to protect it from
conventional electrical abnormalities with the levels listed in the safety table. Applications for use within rural agricultural, heavy industrial,
and other areas or regions which are prone to ‘dirty’ electrical conditions which would subject any of the above models to excessive
voltages surges or spikes, may damage or cause early life failure of product. In this case consideration should be made by the end user to
ensure that adequate line or mains surge suppression is installed in front of Aimtec device to ensure the longevity of the products. Failure
to identify excessive line surges violations prior to installation may damage sensitive equipment permanently.
Input Specifications
Parameters
Current (full load)
Inrush current <2ms(cold start)
Leakage current
Power factor
External fuse
Start-up time
Conditions
115 VAC
230 VAC
277 VAC
115 VAC
230 VAC
277 VAC
I/O
I/FG, O/FG
115 VAC
230 VAC
277 VAC
Recommended slow blow type
Typical
0.98
0.94
0.90
2.5
1000
Maximum
1500
600
500
40
50
60
0.25
3.5
Units
mA
mA
mA
A
A
A
mA
mA
A
ms
www.aimtec.com
F 052.1e R3.AF
Tel: +1 514 620 2722
1 of 11
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only