FEATURES:
Series AMER150C-CAZ
up to 6.3A | AC-DC / DC-DC | LED Driver / Converter
• Constant Current or Constant Voltage LED • Over Voltage Protection
Driver or Converter
• Over Current Protection
• Input range 90-305VAC/47-440Hz
• Waterproof Case rated IP68
• High Efficiency up to 89%
• Power Factor Correction
• 115VAC Operating temperature -50 to 80°C • Short Circuit Protection
Models
Single output
• 230VAC Operating temperature -55 to 80°C
• Dimmable via resistive / 0-10Vdc / PWM
• 5 Years Limited Warranty
Model
Max
Output
Power
(W)①
Output
Voltage
Range
(V)③
Output
Current
(A)③
Input
Input
Voltage Voltage
(VAC/Hz) (VDC)
Mode of
Operation
Efficiency
(%)
115 230 277
VAC
VAC
VAC
AMER150C-50300CAZ
150
36-50
0-3
90-305/47-
440
130-430
Constant Current
Constant Voltage②
87
87
89
88
89
89
AMER150C-36420CAZ
150
24-36
0-4.16
90-305/47-
440
130-430
Constant Current
Constant Voltage②
86
86
88
88
88
88
AMER150C-24630CAZ
144
12-24
0-6.3
90-305/47-
440
130-430
Constant Current
Constant Voltage②
85
85
87
87
87
87
① Exceeding the maximum output power will permanently damage the converter
③ In constant current mode output current is maximum shown, in constant voltage mode output voltage is the maximum shown.
All models can be ordered with optional North American colour input wires (black (L), white (N), green (GND)). Add “–NA” to part number
when ordering.
NOTE: Aimtec limited warranty of 5 years is valid based on product operation at datasheet specifications at ambient temperature of 25°C,
humidity<75%, nominal input voltage (115/230/277VAC) and at rated output load unless otherwise specified.
See http://www.aimtec.com/terms-sale
AMER150C-CAZ’s AC/DC LED drivers have electrical safeguards designed within to protect it from conventional electrical abnormalities
with the levels listed in the safety table. Applications for use within rural agricultural, heavy industrial, and other areas or regions which are
prone to ‘dirty’ electrical conditions which would subject any of the above models to excessive voltages surges or spikes, may damage or
cause early life failure of product. In this case consideration should be made by the end user to ensure that adequate line or mains surge
suppression is installed in front of Aimtec device to ensure the longevity of the products. Failure to identify excessive line surges violations
prior to installation may damage sensitive equipment permanently.
Input Specifications
Parameters
Current (full load)
Inrush current <2ms (cold start)
Leakage current
Power factor
External fuse
Start-up time
Conditions
115 VAC
230 VAC
277 VAC
115 VAC
230 VAC
277 VAC
I/O
I/FG, O/FG
115 VAC
230 VAC
277 VAC
Recommended slow blow type
Typical
0.98
0.94
0.92
3.5
900
Maximum
2000
1000
900
50
75
90
0.25
3.5
Units
mA
mA
mA
A
A
A
mA
mA
A
ms
www.aimtec.com
F 052.1e R3.J
Tel: +1 514 620 2722
1 of 7
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only