English
Language : 

AMER150C-50300AZ Datasheet, PDF (1/7 Pages) AIMTEC – LED Driver / Converter
Click on Series name for product info on aimtec.com
Series AMER150C-AZ
up to 6.3A | AC-DC / DC-DC | LED Driver / Converter
FEATURES:
• AC-DC Constant Current or Constant
Voltage LED Driver
• Over Voltage Protection
• Over Current Protection
• Input range 90-305VAC/47-440Hz
• Waterproof Case rated IP68
• High Efficiency up to 89%
• Power Factor Correction
• Operating temperature -40 to 80°C
• Short Circuit Protection
• Dimmable via resistive / 0-10Vdc / PWM • Over Temperature Protection
Models
• 5 Years Limited Warranty
Single output
Model
Max
Output
Power
(W)①
Output
Voltage
Range
(V)③
Output
Current
(A)③
Input
Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Mode of Operation
Efficiency
(%)
115 230 277
VAC
VAC
VAC
AMER150C-50300AZ
150
36-50
Constant Current
87 89 89
0-3
90-305/47-440 130-430
Constant Voltage②
87 88 89
AMER150C-42350AZ
147
21-42
0-3.5
Constant Current
86 88 88
90-305/47-440 130-430
Constant Voltage②
86
88
88
AMER150C-36420AZ
150
24-36
0-4.16
90-305/47-440 130-430
Constant Current
Constant Voltage②
86 88 88
86 88 88
AMER150C-24630AZ
144
12-24
0-6.3
90-305/47-440 130-430
Constant Current
Constant Voltage②
85 87 87
85 87 87
① Exceeding the maximum output power will permanently damage the converter
② The dimming feature is not supported when units are used in Constant Voltage mode only,
③ In constant current mode output current is maximum shown, in constant voltage mode output voltage is the maximum shown.
All models can be ordered with optional North American colour input wires (add “–NA” to part number when ordering)
NOTE: Aimtec limited warranty of 5 years is valid based on product operation at datasheet specifications at ambient temperature of 25°C,
humidity<75%, nominal input voltage (115/230/277VAC) and at rated output load unless otherwise specified. See
http://www.aimtec.com/terms-sale
AMER150C-AZ’s AC/DC LED drivers have electrical safeguards designed within to protect it from conventional electrical abnormalities with
the levels listed in the safety table. Applications for use within rural agricultural, heavy industrial, and other areas or regions which are
prone to ‘dirty’ electrical conditions which would subject any of the above models to excessive voltages surges or spikes, may damage or
cause early life failure of product. In this case consideration should be made by the end user to ensure that adequate line or mains surge
suppression is installed in front of Aimtec device to ensure the longevity of the products. Failure to identify excessive line surges violations
prior to installation may damage sensitive equipment permanently.
Input Specifications
Parameters
Current (full load)
Inrush current <2ms (cold start)
Leakage current
Power factor
External fuse
Start-up time
Conditions
115 VAC
230 VAC
277 VAC
115 VAC
230 VAC
277 VAC
I/O
I/FG, O/FG
115 VAC
230 VAC
277 VAC
Recommended slow blow type
Typical
0.98
0.94
0.92
3.5
900
Maximum
2000
1000
900
50
75
90
0.25
3.5
Units
mA
mA
mA
A
A
A
mA
mA
A
ms
www.aimtec.com
F 052.1e R3.E
Tel: +1 514 620 2722
1 of 7
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only