AMER150-CAZ_13 Datasheet, PDF (1/10 Pages) AIMTEC – up to 6.3A | AC-DC / DC-DC | LED Driver / Converter | |||
|
Series AMER150-CAZ
up to 6.3A | AC-DC / DC-DC | LED Driver / Converter
FEATURES:
⢠Constant Current or Constant Voltage LED ⢠Over Voltage Protection
Driver or Converter
⢠Over Current Protection
⢠Input range 90-305VAC/47-440Hz
⢠Waterproof Case rated IP68
⢠High Efficiency up to 91%
⢠Power Factor Correction
⢠115VAC Operating temperature -50 to 80°C ⢠Short Circuit Protection
Models
Single output
⢠230VAC Operating temperature -55 to 80°C
⢠Dimmable via analog / 0-10V dimming â¡
Model
Max
Output
Power
(W) â
Output
Voltage
Range
(V) â¢
Output
Current
(A) â¢
Input Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Mode of Operation
Efficiency
(%)
Constant Current
91
AMER150-50300CAZ
150
36-50
0-3
90-305/47-440 120-430
Constant Voltage â¡
90
Constant Current
90
AMER150-36420CAZ
150
24-36
0-4.16 90-305/47-440 120-430
Constant Voltage â¡
88
Constant Current
89
AMER150-24630CAZ 151.2
12-24
0-6.3
90-305/47-440 120-430
Constant Voltage â¡
87
Add Suffix â-Fâ No dimming option
â Exceeding the maximum output power will permanently damage the converter.
â¡ The dimming feature is not supported when units are used in Constant Voltage mode only, Aimtec suggests to order â-Fâ No dimming
option in this case.
⢠In constant current mode output current is maximum shown, in constant voltage mode output voltage is the maximum shown.
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Inrush current <2ms
Leakage current
AC current
Power Factor
External fuse
Start up time
Surge voltage
Conditions
115VAC
230VAC
115VAC
230VAC
115VAC
230VAC
115VAC
230VAC
2sec
Typical
50
75
0.75
1
2.2
0.7
900
Maximum
0.98
0.94
250V/3.5A
440
Units
A
mA
A
ms
V
Output Specifications
Parameters
Conditions
Typical
Current accuracy
±3
Line regulation
LL-HL
±1
Load regulation
0-100% load
±3
Ripple & Noise â£
20MHz Bandwidth
100
Hold-up time (min)
45
Current adjustment range
100-0
Minimum Load Voltage
See the models table
⣠Tested with 0.1µF (C/C) or (M/C) and 47µF (E/C) parallel capacitors at the end.
Maximum
Units
%
%
%
mV p-p
ms
%
www.aimtec.com
F 052.1e R3.E
Tel: +1 514 620 2722
1 of 10
Toll free: + 1 888 9 AIMTEC
(924 6832)