up to 6.3A | AC-DC / DC-DC | LED Driver / Converter
FEATURES:
Models
Single output
 Constant Current or Constant Voltage LED  Over Voltage Protection
Driver or Converter
 Over Current Protection
 Input range 90-305VAC/47-440Hz
 Waterproof Case rated IP68
 High Efficiency up to 89%
 Power Factor Correction
 115VAC Operating temperature -50 to 75°C  Short Circuit Protection
 230VAC Operating temperature -55 to 75°C
 Dimmable via resistive
 5 Year Limited Warranty
Model
Max
Output
Power
(W)①
Output
Voltage
Range
(V)③
Output
Current
(A)③
Input
Voltage
(VAC/Hz)
Input
Voltage Mode of Operation
(VDC)
Efficiency
(%)
115
230
277
VAC
VAC
VAC
AMER150-50300CAZ
150
36-50
Constant Current
87 89 89
0-3
90-305/47-440 130-430 Constant Voltage②
87
88
89
AMER150-36420CAZ
150
24-36
0-4.16
90-305/47-440 130-430
Constant Current
Constant Voltage②
86
86
88
88
88
88
AMER150-24630CAZ 151.2
12-24
0-6.3
90-305/47-440 130-430
Constant Current
Constant Voltage②
85
85
87
87
87
87
Add Suffix “-F” No dimming option
① Exceeding the maximum output power will permanently damage the converter
② The dimming feature is not supported when units are used in Constant Voltage mode only, Aimtec suggests to order “-F” No dimming
option in this case.
③ In constant current mode output current is maximum shown, in constant voltage mode output voltage is the maximum shown.
All models can be ordered with optional North American colour input wires (black (L), white (N), green (GND)). Add “–NA” to part number
when ordering.
NOTE: Aimtec limited warranty of 5 years is valid based on product operation at datasheet specifications at ambient temperature of 25°C,
humidity<75%, nominal input voltage (115/230/277VAC) and at rated output load unless otherwise specified. See
http://www.aimtec.com/terms-saleAMER150-CAZ’s AC/DC LED drivers have electrical safeguards designed within to protect it from
conventional electrical abnormalities with the levels listed in the safety table. Applications for use within rural agricultural, heavy industrial,
and other areas or regions which are prone to ‘dirty’ electrical conditions which would subject any of the above models to excessive
voltages surges or spikes, may damage or cause early life failure of product. In this case consideration should be made by the end user to
ensure that adequate line or mains surge suppression is installed in front of Aimtec device to ensure the longevity of the products. Failure
to identify excessive line surges violations prior to installation may damage sensitive equipment permanently.
Input Specifications
Parameters
Current (full load)
Inrush current <2ms (cold start)
Leakage current
Power factor
External fuse
Start-up time
Conditions
115 VAC
230 VAC
277 VAC
115 VAC
230 VAC
277 VAC
I/O
I/FG, O/FG
115 VAC
230 VAC
277 VAC
Recommended slow blow type
Typical
0.98
0.94
0.92
3.5
900
Maximum
2000
1000
900
50
75
90
0.25
3.5
Units
mA
mA
mA
A
A
A
mA
mA
A
ms
www.aimtec.com