English
Language : 

AMER120C-50250CAZ Datasheet, PDF (1/6 Pages) AIMTEC – LED Driver / Converter
Click on Series name for product info on aimtec.com
Series AMER120C-CAZ
up to 5A | AC-DC / DC-DC | LED Driver / Converter
Models
Single output
FEATURES:
• Constant Current or Constant Voltage LED • Over Temperature Protection
Driver or Converter
• Over Current Protection
• Input range 90-305VAC/47-440Hz
• Waterproof Case rated IP68
• High Efficiency up to 88%
• Power Factor Correction
• 115VAC Operating temperature -50 to 85°C • Short Circuit Protection
• 230VAC Operating temperature -55 to 85°C
• Dimmable via resistive / 0-10Vdc / PWM
• 5 Years Limited Warranty
Model
Max
Output
Power
(W)①
Output
Voltage
Range
(V)③
Output
Current
(A)③
Input
Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Mode of Operation
Efficiency
(%)
115 230 277
VAC
VAC
VAC
AMER120C-50250CAZ
125
36-50
0-2.5
90-305/47-440 130-430
Constant Current
Constant Voltage②
87 88 86
87 88 88
AMER120C-36340CAZ 122.4
24-36
0-3.4
90-305/47-440 130-430
Constant Current
Constant Voltage②
87 88 88
87 88 88
AMER120C-24500CAZ
120
12-24
Constant Current
85 86 87
0-5
90-305/47-440 130-430
Constant Voltage② 86 86 87
① Exceeding the maximum output power will permanently damage the converter.
② The dimming feature is not supported when units are used in Constant Voltage mode only.
③ In constant current mode output current is maximum shown, in constant voltage mode output voltage is the maximum shown. All models
can be ordered with optional North American colour input wires (black (L), white (N), green (GND)). Add “–NA” to part number when
ordering.
NOTE: Aimtec limited warranty of 5 years is valid based on product operation at datasheet specifications at ambient temperature of 25°C,
humidity<75%, nominal input voltage (115/230/277VAC) and at rated output load unless otherwise specified.
See http://www.aimtec.com/terms-sale
AMER120C-CAZ’s AC/DC LED drivers have electrical safeguards designed within to protect it from conventional electrical abnormalities
with the levels listed in the safety table. Applications for use within rural agricultural, heavy industrial, and other areas or regions which are
prone to ‘dirty’ electrical conditions which would subject any of the above models to excessive voltages surges or spikes, may damage or
cause early life failure of product. In this case consideration should be made by the end user to ensure that adequate line or mains surge
suppression is installed in front of Aimtec device to ensure the longevity of the products. Failure to identify excessive line surges violations
prior to installation may damage sensitive equipment permanently.
Input Specifications
Parameters
Current (full load)
Inrush current <2ms (cold start)
Leakage current
Power factor
External fuse
Start-up time
Conditions
115 VAC
230 VAC
277 VAC
115 VAC
230 VAC
277 VAC
I/O
I/FG, O/FG
115 VAC
230 VAC
277 VAC
Recommended slow blow type
Typical
0.98
0.94
0.92
3
900
Maximum
1800
800
700
45
60
70
0.25
3.5
Units
mA
mA
mA
A
A
A
mA
mA
A
ms
www.aimtec.com
F 052.1e R3.B
Tel: +1 514 620 2722
1 of 6
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only