English
Language : 

AMER120-CAZ Datasheet, PDF (1/10 Pages) AIMTEC – up to 5A | AC-DC / DC-DC | LED Driver / Converter
Series AMER120-CAZ
up to 5A | AC-DC / DC-DC | LED Driver / Converter
FEATURES:
 Constant Current or Constant Voltage LED  Over Temperature Protection
Driver or Converter
 Over Current Protection
 Input range 90-305VAC/47-440Hz
 Waterproof Case rated IP68
 High Efficiency up to 91%
 Power Factor Correction
 115VAC Operating temperature -50 to 85°C  Short Circuit Protection
Models
Single output
 230VAC Operating temperature -55 to 85°C
 Dimming via analog / 0-10V dimming ②
Model
Max
Output
Power
(W) ①
Output
Voltage
Range (V) ③
Output
Current
(A) ③
Input
Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Mode of
Operation
Efficiency
(%)
AMER120-50250CAZ
125
36-50
Constant Current
91
0-2.5
90-305/47-440 120-430 Constant Voltage ②
90
AMER120-36340CAZ
122.4
24-36
Constant Current
90
0-3.4
90-305/47-440 120-430 Constant Voltage ②
89
AMER120-24500CAZ
120
12-24
Constant Current
89
0-5
90-305/47-440 120-430 Constant Voltage ②
87
Add Suffix “-F”
No dimming option
① Exceeding the maximum output power will permanently damage the converter
② The dimming feature is not supported when units are used in Constant Voltage mode only, Aimtec suggests to order “-F” No dimming
option in this case.
③ In constant current mode output current is maximum shown, in constant voltage mode output voltage is the maximum shown.
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Inrush current <2ms
Leakage current
AC current
Power Factor
External fuse
Start up time
Surge voltage
Conditions
115VAC
230VAC
115VAC
230VAC
115VAC
230VAC
115VAC
240VAC
2sec
Typical
45
60
0.5
0.75
1.8
0.7
900
Maximum
0.98
0.94
250V/3A
440
Units
A
mA
A
ms
V
Output Specifications
Parameters
Conditions
Typical
Current accuracy
±3
Line regulation
LL-HL
±1
Load regulation
0-100% load
±3
Ripple & Noise ④
20MHz Bandwidth
100
Hold-up time
80
Current adjustment range
100-0
Minimum Load Voltage
See the models table
④ Tested with 0.1µF (M/C) or (C/C) and 47µF (E/C) parallel capacitors at the end.
Maximum
Units
%
%
%
mV p-p
ms
%
www.aimtec.com
F 052.1e R3.D
Tel: +1 514 620 2722
1 of 10
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only