English
Language : 

AMEPR8D-AZ_16 Datasheet, PDF (1/4 Pages) AIMTEC – up to 0.7A | AC-DC LED Driver
Click on Series name for product info on aimtec.com
Series AMEPR8D-AZ
up to 0.7A | AC-DC LED Driver
FEATURES:
• AC-DC Constant Current LED Driver
• Input Range 90-264VAC/47-440Hz
• High Efficiency up to 80%
• Operating Temperature -20 to 85°C
• Total Harmonic Distortion < 20%
Models
Single output
Model
Max Output
Power
(W)①
Output
Voltage
Range
(V)
No Load
Output
Voltage
(V max.)
Output
Current
(A)
AMEPR8D-2435AZ
8.4
12-24
34
0.35
AMEPR8D-1840AZ
7.2
9-18
20
0.4
AMEPR8D-1270AZ
8.4
6-12
15
0.7
*Exceeding the maximum output power will permanently damage the converter.
• IP67 Case
• Active PFC and TRIAC dimmable
• SCP, Over Load Protection
• Leading or Trailing Edge Triac
Input Voltage
(VAC/Hz)
90-264/47-440
90-264/47-440
90-264/47-440
Efficiency
(%)
115
VAC
230
VAC
79
80
77
79
75
78
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
AMEPR8D-AZ’s AC/DC LED drivers have electrical safeguards designed within to protect it from conventional electrical abnormalities with
the levels listed in the safety table. Applications for use within rural agricultural, heavy industrial, and other areas or regions which are
prone to ‘dirty’ electrical conditions which would subject any of the above models to excessive voltages surges or spikes, may damage or
cause early life failure of product. In this case consideration should be made by the end user to ensure that adequate line or mains surge
suppression is installed in front of Aimtec device to ensure the longevity of the products. Failure to identify excessive line surges violations
prior to installation may damage sensitive equipment permanently.
Input Specifications
Parameters
Current (full load)
Inrush current <2ms (cold start)
Leakage current
Power factor
External fuse
Start-up time
Conditions
115 VAC
230 VAC
115 VAC
230 VAC
230 VAC
115 VAC (full load)
230 VAC (full load)
Recommended slow blow type
Typical
1
100
Maximum
85
50
10
5
0.02
0.98
0.95
Units
mA
mA
A
A
mA
A
ms
Output Specifications
Parameters
Conditions
Typical
Maximum
Current accuracy
±15
Line regulation
(LL-HL)
±0.5
Load regulation
min.-max. load
±5
Ripple & Noise*
1.6
Hold-up time
28
Minimum load voltage
See the models table
Maximum Capacitive Load
200
*Ripple and Noise are measured at 20MHz bandwidth by using a 0.1μF (M/C) or (C/C) and 220µF (E/C) parallel capacitor.
Units
%
%
%
V p-p
ms
µF
www.aimtec.com
F 052.1e R3.G
Tel: +1 514 620 2722
1 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only