English
Language : 

AMEPR60-AZ Datasheet, PDF (1/12 Pages) AIMTEC – up to 5A | AC-DC LED driver
Series AMEPR60-AZ
up to 5A | AC-DC / DC-DC | LED Driver / Converter
FEATURES:
• AC-DC Constant Current or Constant
• Over Temperature Protection
Voltage LED Driver
• Over Current Protection
• Input range 90-305VAC/47-440Hz
• Waterproof Case rated IP68
• High Efficiency up to 89%
• Power Factor Correction
• Operating temperature -40 to 85°C
• Short Circuit Protection
Models
• Dimmable via analog / 0-10V dimming ②
Single output
Model
Output
Voltage
Range (V) ③
Output
Current
(A) ③
Input
Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Mode of
Operation
Max
Output
Power
(W) ①
Efficiency
(%)
Constant
60
89
AMEPR60-50120AZ
36-50
0-1.27
90-305/47-440 120-430
Current
Constant
63.8
86
Voltage ②
Constant
59.8
88
AMEPR60-36170AZ
24-36
0-1.77
90-305/47-440 120-430
Current
Constant
63.7
86
Voltage ②
Constant
60
87
AMEPR60-24250AZ
12-24
0-2.55
90-305/47-440 120-430
Current
Constant
61
85
Voltage ②
Constant
60
85
AMEPR60-12500AZ
5-12
0-5.2
90-305/47-440 120-430
Current
Constant
62
82
Voltage ②
① Exceeding the maximum output power will permanently damage the converter
② The dimming feature is not supported when units are used in Constant Voltage mode only.
③ In constant current mode output current is maximum shown, in constant voltage mode output voltage is the maximum shown.
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Inrush current <2ms
Leakage current
AC current
Power Factor
External fuse
Start up time
Surge voltage
Conditions
115VAC
230VAC
115VAC
230VAC
115VAC
230VAC
115VAC
230VAC
2sec
Typical
30
50
0.5
0.7
0.73
0.33
250
Maximum
0.97
0.93
250V/1.5A
440
Units
A
mA
A
ms
V
Output Specifications
Parameters
Current accuracy (CC Mode)
Voltage accuracy (CV Mode)
Line regulation
Load regulation
Ripple & Noise ④
www.aimtec.com
F 052.1e R3.R
Conditions
LL-HL
0-100% load
20MHz Bandwidth
Typical
±3
±3
±1
±3
75
Tel: +1 514 620 2722
1 of 12
Maximum
Units
%
%
%
%
mV p-p
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only