English
Language : 

AMEPR5-AZ_16 Datasheet, PDF (1/3 Pages) AIMTEC – up to 1A | AC-DC / DC-DC LED driver
Click on Series name for product info on aimtec.com
Series AMEPR5-AZ
up to 1A | AC-DC / DC-DC LED driver
FEATURES:
 AC-DC or DC-DC Constant current LED Driver
 Input range 90-264VAC/47-440Hz
 Operating temperature 0 to 80°C
 High Efficiency up to 79%
 5 Years Limited Warranty
 SCP, Over Voltage Protection
 Waterproof Case rated IP67
 No load consumption <0.3W
Models
Single output
Model
Max
Output
Power
(W) ①
Output
Voltage
Range (V)
Output
Current
(A)
Input Voltage
(VAC/Hz)
AMEPR5-1630AZ
4.8
8-16
0.3
90-264/47-440
AMEPR5-1435AZ
4.9
6-14
0.35
90-264/47-440
AMEPR5-1236AZ
4.32
5-12
0.36
90-264/47-440
AMEPR5-0670AZ
4.2
2-6
0.7
90-264/47-440
AMEPR5-05100AZ
5
3-5
1
90-264/47-440
① Exceeding the maximum output power will permanently damage the converter
Input Voltage
(VDC)
130-370
130-370
130-370
130-370
130-370
Efficiency
(%)
115
230
VAC
VAC
79
75
77
74
77
74
76
73
74
72
NOTE: Aimtec limited warranty of 5 years is valid based on product operation at datasheet specifications at ambient temperature of 25°C,
humidity<75%, nominal input voltage (115/230VAC) and at rated output load unless otherwise specified. See http://www.aimtec.com/terms-
sale
AMEPR5-AZ’s AC/DC LED drivers have electrical safeguards designed within to protect it from conventional electrical abnormalities with
the levels listed in the safety table. Applications for use within rural agricultural, heavy industrial, and other areas or regions which are
prone to ‘dirty’ electrical conditions which would subject any of the above models to excessive voltages surges or spikes, may damage or
cause early life failure of product. In this case consideration should be made by the end user to ensure that adequate line or mains surge
suppression is installed in front of Aimtec device to ensure the longevity of the products. Failure to identify excessive line surges violations
prior to installation may damage sensitive equipment permanently.
Input Specifications
Parameters
Inrush current <2ms
Leakage current
AC current
No load consumption
External fuse
Start up time
Conditions
115VAC
230VAC
115VAC
230VAC
115VAC
230VAC
115VAC
230VAC
Typical
15
30
0.2
0.25
0.09
0.06
0.1
0.2
140
Maximum
250V/0.5A
Units
A
mA
A
W
ms
Output Specifications
Parameters
Conditions
Typical
Maximum
Units
Current accuracy
±10
%
Line regulation
LL-HL
±5
%
Load regulation
0-100% load
±10
%
Ripple & Noise ②
6/12/14/16V models
100
5V model
150
mV p-p
Hold-up time
2
ms
Minimum Load Voltage
See the models table
② Ripple and Noise are measured at 20MHz bandwidth by using a 0.1μF (M/C) or (C/C) and 220µF (E/C) parallel capacitor.
www.aimtec.com
F 052.1e R3.L
Tel: +1 514 620 2722
1 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only