AMEPR30-AZ_13 Datasheet, PDF (1/14 Pages) AIMTEC – up to 2.5A | AC-DC / DC-DC | LED Driver / Converter
FEATURES:
Series AMEPR30-AZ
up to 2.5A | AC-DC / DC-DC | LED Driver / Converter
• AC-DC Constant Current or Constant
• Over temperature protection
Voltage LED Driver
• Over current protection
• Input range 90-305VAC/47-440Hz
• Waterproof case rated IP68
• High efficiency up to 86%
• Power Factor Correction
• Operating temperature -40 to 85°C
• Short circuit protection
Models
• Dimmable via analog / 0-10V dimming ②
Single output
Model
Output
Voltage
Range
(V) ③
Output
Current
(A) ③
Input
Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Mode of
Operation
OCP /
OVP
Max
Output
Power
(W) ①
Efficiency
(%)
AMEPR30-5070AZ
36-50
0 - 0.70
90-305 /
47-440
Constant Current
0.77
120-430 Constant Voltage ② 50.7
35
38.5
86
85
AMEPR30-4864AZ
36-48
0 - 0.64
90-305 /
47-440
Constant Current
0.66
120-430 Constant Voltage ② 48.6
30.7
31.7
86
84
AMEPR30-36100AZ
24-36
0 - 1.0
90-305 /
47-440
Constant Current
1.04
120-430 Constant Voltage ② 36.6
36
37.4
85
84
AMEPR30-24140AZ
12-24
0 - 1.4
90-305 /
47-440
Constant Current
1.45
120-430 Constant Voltage ② 24.5
33.6
34.8
84
84
AMEPR30-12250AZ
5-12
0 - 2.5
90-305 /
47-440
Constant Current
2.55
120-430 Constant Voltage ② 12.3
30
30.6
83
83
① Exceeding the maximum output power will permanently damage the converter
② The dimming feature is not supported when units are used in Constant Voltage mode only.
③ In constant current mode output current is maximum shown, in constant voltage mode output voltage is the maximum
shown.
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Inrush current <2ms
Leakage current
AC current
Power Factor
External fuse
Start up time
Conditions
115VAC
230VAC
115VAC
230VAC
115VAC
230VAC
115VAC
230VAC
Typical
25
40
0.3
0.5
0.43
0.25
450
Maximum
0.96
0.90
250V/1A
Units
A
mA
A
ms
Output Specifications
Parameters
Conditions
Typical
Current accuracy
±2
Line regulation
LL-HL
±1
Load regulation
0-100% load
±2
Ripple & Noise ④
20MHz Bandwidth
75
Hold-up time
50
Current adjustment range
100-0
Minimum Load Voltage
See the models table
④ Tested with 0.1µF (C/C) or (M/C) and 47µF (E/C) parallel capacitors at the end.