English
Language : 

AMEPR15D-AZ_16 Datasheet, PDF (1/5 Pages) AIMTEC – up to 1A | AC-DC LED Driver
Click on Series name for product info on aimtec.com
Series AMEPR15D-AZ
up to 1A | AC-DC LED Driver
FEATURES:
 AC-DC Constant Current LED Driver
 Input range 90-264VAC/47-440Hz
 High Efficiency up to 82%
 Operating temperature -20 to 80°C
 Total Harmonic Distortion < 20%
 Leading or Trailing Edge Triac
 IP20 or IP67 Case
 Active PFC with TRIAC Dimmable②
 SCP, Over Load Protection
Models
 5 Year Limited Warranty
Single Output
Model
Max
Output
Power
(W)①
Output
Voltage
Range
(V)
No Load
Output
Voltage
(V max.)
Output
Input Voltage
Current (A)
(VAC/Hz)
Efficiency
(%)
115
VAC
230
VAC
AMEPR15D-5030AZ+Suffix②
15
36-50
62
0.3
90-264/47-440
82
82
AMEPR15D-4835AZ+Suffix②
15.8
30-48
62
0.35
90-264/47-440
82
82
AMEPR15D-3650AZ+Suffix②
18
24-36
52
0.5
90-264/47-440
81
82
AMEPR15D-2470AZ+Suffix②
16.8
12-24
34
0.7
90-264/47-440
81
82
AMEPR15D-15100AZ+Suffix②
15
8-15
23
1
90-264/47-440
80
79
①Exceeding the maximum output power will permanently damage the converter.
②Model Nomenclature for Ordering:
Add Suffix “-UD”
Universal AC input 90-264VAC, (no TRIAC dimming option), IP20
Add Suffix “-UW”
Universal AC input 90-264VAC, (no TRIAC dimming option), IP67
Add Suffix “-110D”
AC input 90-135VAC, IP20, 115VAC typical value
Add Suffix “-110W”
AC input 90-135VAC, IP67, 115VAC typical value
Add Suffix “-220D”
AC input 180-264VAC, IP20, 230VAC typical value
Add Suffix “-220W”
AC input 180-264VAC, IP67, 230VAC typical value
NOTE: Aimtec limited warranty of 5 years is valid based on product operation at datasheet specifications at ambient temperature of 25°C,
humidity<75%, nominal input voltage (115/230VAC) and at rated output load unless otherwise specified. See http://www.aimtec.com/terms-
sale
AMEPR15D-AZ’s AC/DC LED drivers have electrical safeguards designed within to protect it from conventional electrical abnormalities with
the levels listed in the safety table. Applications for use within rural agricultural, heavy industrial, and other areas or regions which are
prone to ‘dirty’ electrical conditions which would subject any of the above models to excessive voltages surges or spikes, may damage or
cause early life failure of product. In this case consideration should be made by the end user to ensure that adequate line or mains surge
suppression is installed in front of Aimtec device to ensure the longevity of the products. Failure to identify excessive line surges violations
prior to installation may damage sensitive equipment permanently.
Input Specifications
Parameters
Inrush current <2ms (cold start)
Leakage current
AC current
Power Factor
External fuse
Start up time
Conditions
115VAC
230VAC
115VAC
230VAC
115VAC
230VAC
Recommend Slow
Blown Type
Typical
1
200
Maximum
15
25
25
400
250
0.9
0.9
Units
A
mA
mA
A
ms
www.aimtec.com
F 052.1e R3.R
Tel: +1 514 620 2722
1 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only