English
Language : 

AMEPR10D-AZ_16 Datasheet, PDF (1/4 Pages) AIMTEC – up to 0.7A | AC-DC LED driver
Click on Series name for product info on aimtec.com
Series AMEPR10D-AZ
up to 0.7A | AC-DC LED driver
FEATURES:
 AC-DC Constant current LED Driver
 Input range 90-264VAC/47-440Hz
 High Efficiency up to 81%
 Over Temperature Protection
 IP20 and IP67 Case
 Active PFC with TRIAC dimmable②
 Operating temperature -20 to 80°C
 Total Harmonic Distortion < 20%
 SCP, Over Voltage Protection
 Leading or Trailing Edge Triac
Models
 5 Year Limited Warranty
Single output
Model
Max
Output
Power
(W) ①
Output
Voltage
Range
(V)
No Load
Output
Voltage
(V max.)
Output
Current
(A)
Input Voltage
(VAC/Hz)
Efficiency
(%)
115
VAC
230
VAC
AMEPR10D-5020AZ+Suffix②
10
36-50
62
0.2
90-264/47-440
78
79
AMEPR10D-4025AZ+Suffix②
10
30-40
62
0.25
90-264/47-440
81
80
AMEPR10D-3630AZ+Suffix②
10.8
24-36
52
0.3
90-264/47-440
80
81
AMEPR10D-3035AZ+Suffix②
10.5
15-30
34
0.35
90-264/47-440
77
78
AMEPR10D-1564AZ+Suffix②
9.6
8-15
23
0.64
90-264/47-440
77
76
AMEPR10D-1270AZ+Suffix②
8.4
5-12
23
0.7
90-264/47-440
78
79
① Exceeding the maximum output power will permanently damage the converter.
② Model Nomenclature for Ordering:
Add Suffix “-UD”
Universal AC input 90-264VAC (no TRIAC dimming option), IP20
Add Suffix “-UW”
Universal AC input 90-264VAC (no TRIAC dimming option), IP67
Add Suffix “-110D”
AC input 90-135VAC, IP20
Add Suffix “-110W”
AC input 90-135VAC, IP67
Add Suffix “-220D”
AC input 180-264VAC, IP20
Add Suffix “-220W”
AC input 180-264VAC, IP67
NOTE: Aimtec limited warranty of 5 years is valid based on product operation at datasheet specifications at ambient temperature of 25°C,
humidity<75%, nominal input voltage (115/230VAC) and at rated output load unless otherwise specified. See http://www.aimtec.com/terms-
sale
AMEPR10D-AZ’s AC/DC LED drivers have electrical safeguards designed within to protect it from conventional electrical abnormalities with
the levels listed in the safety table. Applications for use within rural agricultural, heavy industrial, and other areas or regions which are
prone to ‘dirty’ electrical conditions which would subject any of the above models to excessive voltages surges or spikes, may damage or
cause early life failure of product. In this case consideration should be made by the end user to ensure that adequate line or mains surge
suppression is installed in front of Aimtec device to ensure the longevity of the products. Failure to identify excessive line surges violations
prior to installation may damage sensitive equipment permanently.
Input Specifications
Parameters
Inrush current <2ms (cold start)
Leakage current
Current (Full Load)
Power Factor
External fuse (slow blow)
Start up time
Conditions
115VAC
230VAC
115VAC
230VAC
115VAC
230VAC
115VAC
230VAC
Recommended slow blow Type
Typical
15
25
0.2
0.25
110
55
1
200
Maximum
0.9
0.9
Units
A
mA
mA
A
ms
www.aimtec.com
F 052.1e R3.P
Tel: +1 514 620 2722
1 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only