AMEOR60C-AZ Datasheet, PDF (1/14 Pages) AIMTEC – Over Temperature Protection
FEATURES:
Click on Series name for product info on aimtec.com
Series AMEOR60C-AZ
up to 5A | AC-DC / DC-DC LED driver
 AC-DC Constant current LED Driver
 Input range 90-305VAC/47-440Hz
 High Efficiency up to 89%
 Operating temperature -40 to 80°C
 Dimmable via Analog / 0-10Vdc / PWM
 Over Temperature Protection
 Open frame
 Power Factor Correction
 SCP, Over Current Protection
 5 Year Limited Warranty
Models
Single output
Model
Max
Output
Power
(W) *
Output
Voltage
Range (V)
Output
Current
(A)
Input Voltage
(VAC/Hz)
Input Voltage
(VDC)
Efficiency
(%)
AMEOR60C-50120AZ
60
36-50
1.2
90-305/47-440
130-430
89
AMEOR60C-36170AZ
59.8
24-36
1.66
90-305/47-440
130-430
88
AMEOR60C-24250AZ
60
12-24
2.5
90-305/47-440
130-430
87
AMEOR60C-12500AZ
60
5-12
5
90-305/47-440
130-430
85
*Exceeding the maximum output power will permanently damage the converter
All models can be ordered with optional North American colour input wires (black (L), white (N), green (GND)). Add “–NA” to
part number when ordering.
NOTE: Aimtec limited warranty of 5 years is valid based on product operation at datasheet specifications at ambient temperature of 25°C,
humidity<75%, nominal input voltage (115/230/305VAC) and at rated output load unless otherwise specified. See
http://www.aimtec.com/terms-sale
AMEOR60C-AZ’s AC/DC LED drivers have electrical safeguards designed within to protect it from conventional electrical abnormalities with
the levels listed in the safety table. Applications for use within rural agricultural, heavy industrial, and other areas or regions which are
prone to ‘dirty’ electrical conditions which would subject any of the above models to excessive voltages surges or spikes, may damage or
cause early life failure of product. In this case consideration should be made by the end user to ensure that adequate line or mains surge
suppression is installed in front of Aimtec device to ensure the longevity of the products. Failure to identify excessive line surges violations
prior to installation may damage sensitive equipment permanently.
Input Specifications
Parameters
Inrush current <2ms
Leakage current
AC current
Power Factor
External fuse
Start up time
Surge voltage
Conditions
115VAC
230VAC
115VAC
230VAC
115VAC
230VAC
115VAC
230VAC
2sec
Typical
30
50
0.5
0.75
0.67
0.33
250
Maximum
0.99
0.97
250V/1.5A
440
Units
A
mA
A
ms
V
Output Specifications
Parameters
Conditions
Typical
Current accuracy
±3
Line regulation
LL-HL
±1
Load regulation
0-100% load
±3
Ripple & Noise *
20MHz Bandwidth
75
Hold-up time
90
Current adjustment range
100-0
Minimum Load Voltage
See the models table
* Tested with 0.1µF (M/C) or (C/C) and 10µF (E/C) parallel capacitors at the end.
Maximum
Units
%
%
%
mV p-p
ms
%
www.aimtec.com
F 052.1e R3.D
Tel: +1 514 620 2722
1 of 14
Toll free: + 1 888 9 AIMTEC
(924 6832)