English
Language : 

AMEOR30C-AZ_16 Datasheet, PDF (1/17 Pages) AIMTEC – up to 2.5A | AC-DC / DC-DC LED driver
FEATURES:
Click on Series name for product info on aimtec.com
Series AMEOR30C-AZ
up to 2.5A | AC-DC / DC-DC LED driver
 AC-DC Constant current LED Driver
 Input range 90-305VAC/47-440Hz
 High Efficiency up to 86%
 Operating temperature -40 to 80°C
 Dimmable via Analog / 0-10Vdc / PWM
 Over Temperature Protection
 Open frame
 Power Factor Correction
 SCP, Over Current Protection
 5 Year Limited Warranty
Models
Single output
Model
Max Output
Power (W) *
Output
Voltage
Range (V)
Output
Current
(A)
Input Voltage
(VAC/Hz)
Input Voltage
(VDC)
Efficiency
(%)
AMEOR30C-5070AZ
35
36-50
0.7
90-305/47-440
130-430
86
AMEOR30C-4864AZ
30.72
36-48
0.64
90-305/47-440
130-430
86
AMEOR30C-36100AZ
36
24-36
1
90-305/47-440
130-430
85
AMEOR30C-24140AZ
33.6
12-24
1.4
90-305/47-440
130-430
84
AMEOR30C-12250AZ
30
5-12
2.5
90-305/47-440
130-430
83
*Exceeding the maximum output power will permanently damage the converter
All models can be ordered with optional North American colour input wires (black (L), white (N), green (GND)). Add “–NA” to
part number when ordering.
NOTE: Aimtec limited warranty of 5 years is valid based on product operation at datasheet specifications at ambient temperature of 25°C,
humidity<75%, nominal input voltage (115/230/305VAC) and at rated output load unless otherwise specified. See
http://www.aimtec.com/terms-sale
AMEOR30C-AZ’s AC/DC LED drivers have electrical safeguards designed within to protect it from conventional electrical abnormalities with
the levels listed in the safety table. Applications for use within rural agricultural, heavy industrial, and other areas or regions which are
prone to ‘dirty’ electrical conditions which would subject any of the above models to excessive voltages surges or spikes, may damage or
cause early life failure of product. In this case consideration should be made by the end user to ensure that adequate line or mains surge
suppression is installed in front of Aimtec device to ensure the longevity of the products. Failure to identify excessive line surges violations
prior to installation may damage sensitive equipment permanently.
Input Specifications
Parameters
Inrush current <2ms
Leakage current
AC current
Power Factor
External fuse
Start up time
Surge voltage
Conditions
115VAC
230VAC
115VAC
230VAC
115VAC
230VAC
115VAC
230VAC
2sec
Typical
25
40
0.3
0.5
0.33
0.16
450
Maximum
0.99
0.97
250V/1A
440
Units
A
mA
A
ms
V
Output Specifications
Parameters
Conditions
Typical
Current accuracy
±3
Line regulation
LL-HL
±1
Load regulation
0-100% load
±3
Ripple & Noise *
20MHz Bandwidth
75
Hold-up time
50
Current adjustment range
100-0
Minimum Load Voltage
See the models table
* Tested with 0.1µF (M/C) or (C/C) and 47µF (E/C) parallel capacitors at the end.
www.aimtec.com
Tel: +1 514 620 2722
F 052.1e R3.D
1 of 17
Maximum
Units
%
%
%
mV p-p
ms
%
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only